@chrischall/iaqualink-mcp
v0.2.2
Published
iAqualink (Zodiac/Fluidra) pool equipment MCP server for Claude — status plus confirm-gated pump, heater, light, aux and set-point control. Developed and maintained by AI (Claude Code).
Maintainers
Readme
iaqualink-mcp
MCP server for iAqualink (Zodiac / Jandy / Fluidra) pool and spa equipment. Read temperatures, set points, pumps, heaters, lights, aux circuits and salt chlorinator state, and switch equipment — every change confirmation-gated and verified by a re-read. It signs in with your own iAqualink account (the same email and password as the iAqualink app); no browser, extension or bridge.
Supports the two system types the reference client supports: iAqua (Jandy iAquaLink panels) and eXO (Zodiac salt chlorinators). Other device types on the account (robotic cleaners, …) are listed but not controlled.
Status: partly verified live. Request shapes come from iaqualink-py 0.7.0 (what Home Assistant uses) and a WebTouch capture (see docs/IAQUALINK-API.md).
- Seen working on a real iAqua (RS) panel, 2026-10-11/12: sign-in, the system list (
devices.json), the iAqua status reads (get_home,get_devices) and WebTouch (location lookup, init, button presses and the display stream).- Still derived, not yet exercised live: the iAqua
set_*commands (pump, heater, aux, light, temperature), every eXO request (shadow read and writes),iaqualink_set_chlorinator's inferred shape, and the iQ20 schedule fallback. Every write still re-reads to confirm what happened.
This project was developed and is maintained by AI (Claude Code). Use at your own discretion.
Tools
| Tool | What it does | Annotation |
| --- | --- | --- |
| iaqualink_list_systems | Systems on the account and their serials | read |
| iaqualink_get_status | Temperatures, set points, pumps, heaters, aux/lights, chlorinator, salinity/pH/ORP (view: compact · full · raw) | read |
| iaqualink_healthcheck | Whether a sign-in is configured and accepted | read |
| iaqualink_set_equipment | Pool/spa pump, pool/spa/solar heater; eXO filter pump, production, boost, low, heating — on/off | write, not destructive |
| iaqualink_set_aux | Aux circuit or light on/off (by number, aux_<n> or label) | write, not destructive |
| iaqualink_set_light | Dimmable brightness (0/25/50/75/100) or color effect (iAqua) | write, not destructive |
| iaqualink_set_temperature | Pool and/or spa set point (iAqua °F/°C; eXO °C pool) | write, not destructive |
| iaqualink_set_chlorinator | eXO chlorinator output % — inferred shape, not in iaqualink-py | write, not destructive |
| iaqualink_list_schedules | RS panel programs via WebTouch (iAqua; iQ20 fallback probe); eXO timers | read |
| iaqualink_add_schedule | Add an RS panel program (circuit, start, stop, run days) via WebTouch | write, not destructive |
| iaqualink_edit_schedule | Change an RS panel program's start / stop / run days via WebTouch | write, not destructive |
| iaqualink_delete_schedule | Delete an RS panel program via WebTouch — no undo | write, destructive |
| iaqualink_set_schedule | Set / re-time / disable an eXO timer (start–stop, rpm on variable-speed pumps) — eXO only, unverified live | write, not destructive |
| iaqualink_check_panel | Is an RS system online, and what is its panel showing (screen, open dialog, Edit mode with unsaved changes)? Run it when the app and these tools disagree | read |
| iaqualink_list_pump_speeds | RS panel variable-speed pump: the named speeds, their RPM and which one runs, via WebTouch | read |
| iaqualink_set_pump_speed | Run the pump at a named speed via WebTouch | write, not destructive |
| iaqualink_set_pump_speed_rpm | Change a named speed's RPM (600–3450) via WebTouch; a speed that is not running runs briefly while set, then the running speed is restored | write, not destructive |
| iaqualink_list_onetouch | RS panel OneTouch scenes (Spa Mode, All OFF, …) and their state, via WebTouch | read |
| iaqualink_set_onetouch | Turn a OneTouch scene on/off via WebTouch — toggle not exercised live yet | write, not destructive |
Every write has an inverse in this set and reaches no other person — except deleting a panel program, which the panel stores immediately with no undo, so that one is marked destructive.
Schedules and OneTouch on a Jandy AquaLink RS panel go through
WebTouch, the panel emulation the iAqualink web app uses: the server opens
the panel's display stream, presses the same buttons a person would (checking
before every press that the panel is on the expected screen and row, and
aborting otherwise), returns to Home, and re-reads to verify. Only one WebTouch
session per system runs at a time. The add / edit / delete sequences follow a
live capture on an RS panel (2026-10-11) — see
docs/IAQUALINK-API.md.
If WebTouch is unavailable, iaqualink_list_schedules falls back to iQ20
schedules (adapter firmware 3+), probing r-api.iaqualink.net/v2 (Bearer),
p-api.iaqualink.net/v2 (Bearer), p-api.iaqualink.net/v2 (bare token) and
prm.iaqualink.net/v1 (bare token) once each and reporting every attempt.
iQ20 schedule writes are not built.
How a write works. It reads the current state first and sends nothing if
it already matches — iAqua's pump/heater/aux commands are toggles, so a blind
send would flip whatever the state happened to be. It then asks you to confirm
(an elicitation prompt where the client supports one; otherwise a preview plus
a confirmToken, bound to the state it was planned against), sends, and
re-reads until the requested value shows up. The result is confirmed,
unchanged, or sent-unconfirmed with what was observed (eXO applies changes
asynchronously — check again rather than retrying).
Setup
npm i -g @chrischall/iaqualink-mcp| Variable | Required | Meaning |
| --- | --- | --- |
| IAQUALINK_EMAIL | for every tool | Your iAqualink app sign-in email |
| IAQUALINK_PASSWORD | for every tool | Your iAqualink password (not trimmed) |
| IAQUALINK_STATUS_CACHE_SECONDS | no | Seconds a status read is reused (default 5; 0 disables) |
| IAQUALINK_WEBTOUCH_STREAM_HOSTS | no | Extra hosts (comma-separated) the WebTouch display stream may come from; default only prm.iaqualink.net |
| MCP_CONFIRM_MODE | no | ask-user (default) / auto / refuse |
| MCP_CONFIRM_TTL_SECONDS | no | confirmToken lifetime (default 600) |
| MCP_CONFIRM_ELICITATION | no | off skips the prompt even on clients that declare elicitation |
The server starts without credentials (so hosts can list its tools) and reports them missing on the first call. A rejected password is never retried: the refusal is remembered until the server restarts, so a typo cannot lock the account.
Claude Code: claude mcp add iaqualink -e IAQUALINK_EMAIL=… -e IAQUALINK_PASSWORD=… -- npx -y @chrischall/iaqualink-mcp
Hosted (claude.ai)
mint.yaml declares per-user children with an email/password form on the
connector's authorize page (each person signs in as themselves), egress to
exactly prod.zodiac-io.com, r-api.iaqualink.net, p-api.iaqualink.net
(iQ20 probe only) and prm.iaqualink.net (WebTouch, and the iQ20 probe); the
WebTouch display stream is refused on any other host unless it is added to
IAQUALINK_WEBTOUCH_STREAM_HOSTS (and egress). No persistent
state — the session lives in memory and one sign-in rebuilds it after a cold
start.
Skills
skills/iaqualink— how to use these tools.skills/iaqualink-curl— the same reads straight from a shell withcurl, credentials from the macOS Keychain (the sign-in, system list and iAqua reads are seen live; the eXO shadow read is still derived from iaqualink-py).
Development
npm install
npm run build
npm run test:coverage # typecheck (src + tests) + vitest, 100% coverage — what CI runsTests run the real client against an in-memory iAqualink
(tests/support/fake-server.ts) built from iaqualink-py's fixtures.