@digta/mcprotocol
v1.0.0
Published
Mitsubishi MELSEC MC (MELSEC Communication) protocol client for Ethernet PLCs. Fork of mcprotocol 0.1.2 with a TCP framing fix for ASCII 3E responses.
Maintainers
Readme
@digta/mcprotocol
Mitsubishi MELSEC Communication (MC) protocol client for Ethernet PLCs, written entirely in JavaScript.
This is an @digta-scoped fork of mcprotocol 0.1.2
(by Dana Moffit) with a single behavioural fix: TCP frame reassembly for ASCII
3E responses. It is a drop-in replacement — no API changes. See
CHANGELOG.md for the details.
Part of Protokit.
This software is not affiliated with Mitsubishi. FX3U and MELSEC are trademarks of Mitsubishi.
⚠️ BETA CODE. Wrong values can be written to wrong locations. Test everything thoroughly before using against a live PLC.
Install
npm i @digta/mcprotocolWhat's different from upstream
[email protected] treated every socket data event as exactly one complete PLC
response. TCP is a byte stream, so an ASCII 3E response can be split across
several events — or several responses can arrive in one — which produced
Invalid Response Length / DATA LESS THAN 11 BYTES errors and connection
resets when polling many registers.
This fork buffers incoming bytes per connection and slices out whole frames
using the response data-length field (18 + dataLen chars) before processing.
It is active only for ascii: true + frame: '3E'; every other mode uses
the original code path. Full write-up in CHANGELOG.md.
Usage
var mc = require('@digta/mcprotocol');
var conn = new mc;
var variables = {
TEST1: 'D0,5', // 5 words starting at D0
TEST4: 'R2000,2', // 2 words at R2000
TEST6: 'D6000.1,20', // 20 bits starting at D6000.1
};
conn.initiateConnection({ port: 1281, host: '192.168.0.2', ascii: false }, connected);
function connected(err) {
if (typeof err !== 'undefined') { console.log(err); process.exit(); }
conn.setTranslationCB(function (tag) { return variables[tag]; });
conn.addItems(['TEST1', 'TEST4']);
conn.addItems('TEST6');
conn.readAllItems(valuesReady);
}
function valuesReady(anythingBad, values) {
if (anythingBad) { console.log('SOMETHING WENT WRONG READING VALUES'); }
console.log(values);
process.exit();
}Note: to use the ASCII 3E fix, configure the connection with
{ ascii: true, frame: '3E' }.
API
initiateConnection(params, callback)— connect.params:port,host,ascii(defaultfalse),frame('1E'default,'3E'supported),octalInputOutput(defaulttrue).callback(err).dropConnection()— terminate the TCP connection.setTranslationCB(translator)— map tag names to addresses.translator(tag)returns an address string, e.g.M100,20,D2000,5,DFLOAT1000,RSTR30,10,D1000.2,5.addItems(items)/removeItems(items)— manage the read polling list (string or array of strings).writeItems(items, values, callback)— write values to the PLC.readAllItems(callback)— read the polling list;callback(anythingBad, values).
For the full address syntax and configurator setup notes, see the upstream mcprotocol documentation.
Tested against
Direct connection to FX3U-ENET / FX3U-ENET-ADP. Q-series E71 should work in theory (same frames). Serial and UDP are not supported.
Changelog
1.0.0 — fork of [email protected] with the ASCII 3E TCP frame reassembly fix.
Full details in CHANGELOG.md.
License
MIT — © 2015 Dana Moffit (original), © 2026 Rifky Andigta Al-Fathir (fork modifications).