@digta/modbus
v1.0.0
Published
Modbus TCP client (master) for Node.js — read/write coils and registers with promises. Zero dependencies.
Downloads
11
Maintainers
Readme
@digta/modbus
Modbus TCP client (master) for Node.js. Promise-based, zero dependencies
(uses only the built-in net module).
Part of Protokit.
⚠️ Writing to the wrong register can damage equipment or hurt someone. Test thoroughly against your PLC before writing in production.
Install
npm i @digta/modbusQuick start
const { ModbusTcpClient } = require("@digta/modbus");
const client = new ModbusTcpClient({ host: "192.168.1.10", port: 502, unitId: 1 });
async function main() {
await client.connect();
const regs = await client.readHoldingRegisters(0, 10); // number[] (uint16)
console.log(regs);
await client.writeSingleRegister(4, 1234);
await client.writeMultipleRegisters(0, [1, 2, 3]);
const coils = await client.readCoils(0, 8); // boolean[]
await client.writeSingleCoil(0, true);
client.close();
}
main().catch(console.error);Options
new ModbusTcpClient({
host, // required — PLC IP or hostname
port: 502, // Modbus TCP port
unitId: 1, // slave / unit id
timeout: 2000, // per-request (and connect) timeout, ms
});API
All methods return a Promise. Reads resolve with data; writes resolve with
undefined. Addresses are 0-based.
| Method | FC | Returns |
|--------|----|---------|
| connect() | — | resolves when connected |
| readCoils(address, quantity) | 0x01 | boolean[] |
| readDiscreteInputs(address, quantity) | 0x02 | boolean[] |
| readHoldingRegisters(address, quantity) | 0x03 | number[] (uint16) |
| readInputRegisters(address, quantity) | 0x04 | number[] (uint16) |
| writeSingleCoil(address, boolean) | 0x05 | — |
| writeSingleRegister(address, value) | 0x06 | — |
| writeMultipleCoils(address, boolean[]) | 0x0F | — |
| writeMultipleRegisters(address, number[]) | 0x10 | — |
| close() | — | closes the socket |
| connected (getter) | — | boolean |
Quantity limits follow the spec: reads ≤ 2000 bits or ≤ 125 registers; writes
≤ 1968 coils or ≤ 123 registers. Out-of-range arguments throw a RangeError
before anything is sent.
Error handling
Protocol exceptions and transport failures reject with a ModbusError:
const { ModbusError } = require("@digta/modbus");
try {
await client.readHoldingRegisters(9999, 1);
} catch (err) {
if (err instanceof ModbusError) {
console.error(err.message, err.code); // e.g. "Illegal data address", 2
}
}err.code is the numeric Modbus exception code for protocol errors, or a string
tag for transport issues: ETIMEDOUT, ENOTCONN, ECLOSED, EMISMATCH.
Reading 32-bit / float values
Registers are 16-bit. Combine two for a 32-bit value (word order depends on your device):
const [hi, lo] = await client.readHoldingRegisters(0, 2);
const int32 = (hi << 16) | lo;Scope
This package covers Modbus TCP (master/client). Modbus RTU/ASCII over a serial port is intentionally out of scope — it needs a native serial dependency, which would break the zero-dependency promise. Modbus RTU-over-TCP gateways work fine with this client.
License
MIT © Rifky Andigta Al-Fathir