@emdzej/ediabasx-interface-j2534
v0.7.1
Published
SAE J2534 PassThru transport for EdiabasX via Tactrix OpenPort 2.0 — wraps @emdzej/j2534-driver as an EdiabasInterface, with frame-level integrity that K+DCAN UART bridges can't provide.
Downloads
1,688
Readme
@emdzej/ediabasx-interface-j2534
SAE J2534 PassThru transport for EdiabasX via the Tactrix OpenPort 2.0. Wraps @emdzej/j2534-driver as an EdiabasInterface so any SGBD that runs over the K+DCAN serial path can also run over a frame-level OpenPort.
Requires
@emdzej/j2534-driver(and@emdzej/j2534-types)^0.3.0— declared as peer dependencies so consumers control the version. Optional peers@emdzej/j2534-usb(Node) and@emdzej/j2534-webserial(browser) pick the USB transport.
Why J2534 (vs K+DCAN passthrough)
K+DCAN cables are FTDI USB-UART bridges — fine for fast ECUs but timing-noisy on slow K-line lines. The OpenPort 2.0 is an active J2534 device with its own K-line transceiver, so bit timing, direction switching, and parity are handled in hardware. Verified end-to-end against:
- E46 GS20 transmission (
10GD20.prg IDENT) - E46 KMB46 cluster (
C_KMB46.prg C_ZCS_LESEN— slow EEPROM read, ~250 ms round-trip)
Interface identity: we masquerade as OBD
UTILITY.PRG's INTERFACE job (and any BEST2 xtype / xvers call) reports:
TYP = "OBD"
VERSION = 0xD1 (209)— identical to what BMW's reference OBD32.dll (K+DCAN over FTDI) publishes, even though this transport is actually SAE J2534 over an OpenPort 2.0.
Why: J2534 isn't one of the IFH variants BMW shipped with EDIABAS (the known set is STD:OBD / STD:ADS / STD:OMITEC / ENET). SGBDs that branch on TYP (e.g. if interface_type = "OBD" then ... else ...) would either reject a literal "J2534" or fall through to an untested else-branch. The whole point of this package is "drop-in K+DCAN replacement over OpenPort 2.0" — upper layers should be unable to tell whether the K-line is being driven by an FTDI bridge or a J2534 PassThru device. The masquerade keeps that promise.
The trade-off: a job that legitimately needs to distinguish J2534-from-K+DCAN can't. None of the BMW SGBDs we've encountered do this; if one ever does, the right fix is a separate capability-probe channel, not a different TYP literal.
Values verified via Ghidra of OBD32.dll's WRITEDATA dispatcher (case 0x12 → "OBD\0" literal at _DAT_1000d1d0, case 0x0B → hardcoded 0xD1 immediate). Both constants are static — they don't depend on the Hardware= INI mode or on any on-wire adapter info.
Use
import { Ediabas } from '@emdzej/ediabasx-ediabas';
import { J2534Interface } from '@emdzej/ediabasx-interface-j2534';
const ed = new Ediabas({
ecuPath: '.',
interface: new J2534Interface({
transport: { kind: 'serial' }, // J2534 wire transport: node USB-FTDI driver
protocol: 'ds2', // ds2 | kwp | can
baudRate: 9600,
}),
});
await ed.connect();
ed.loadSgbd('C_KMB46');
const results = await ed.executeJob('C_ZCS_LESEN');
await ed.disconnect();For browser-side use, hand the constructor an instance from @emdzej/j2534-webserial:
import { WebSerialTransport } from '@emdzej/j2534-webserial';
new J2534Interface({
transport: { kind: 'instance', transport: new WebSerialTransport() },
protocol: 'ds2',
baudRate: 9600,
});Slow K-line ECUs
Without a host-side ParRegenTime wait between transactions, OpenPort firmware drops responses from clusters / IKE / body modules (slower than the J2534 P2_MAX window, which Tactrix's DLL doesn't expose). J2534Interface.send() enforces this delay host-side — mirrors Ds2Session.sendRequest() in @emdzej/ediabasx-interface-serial. The SGBD's xsetpar ParRegenTime (parameters[6]) drives the wait. No action needed — works automatically as long as the SGBD calls INITIALISIERUNG.
Some related findings (verified via Ghidra of op20pt32.dll):
- Tactrix's DLL silently drops
SET_CONFIG/GET_CONFIGcalls containingP1_MIN/P2_MIN/P2_MAX/P3_MAX/P4_MAX. The firmware never sees those values via the DLL.@emdzej/j2534-driver0.3.0+ mirrors this blacklist in its ownpassThruIoctl— sending non-default values for those params on OpenPort 2.0 has been observed to corrupt the device's persistent configuration and require a Tactrix EcuFlash firmware reflash to recover. Override the safety withallowUnsafeConfigParams: trueonly when knowingly attempting recovery (e.g. writing the J2534 §6.4 sentinel0xFFFFFFFF= "use default"). - The
att(transmit) USB cmd carries a<timeoutMicros>field — Tactrix defaults to 1 s for K-line.@emdzej/j2534-driver0.2.0+ propagates the J2534Timeoutargument here.
Configuration
| Option | Default | Purpose |
|---|---|---|
| protocol | "ds2" | Wire protocol — ds2 for E36/E39/E46-era K-line, kwp for ISO14230 fast init, can for raw frames. Note: the SGBD's xsetpar overrides this on first job. |
| baudRate | 9600 | K-line baud. Ignored for can. |
| loopback | true | Have OpenPort echo TX back; the interface filters echoes host-side. Matches the j2534 repo's DS2 reference example. |
| hostInterByteMs | 0 | Host-side inter-byte gap. Workaround for ECUs that need K+DCAN-style USB-chunking delays; usually unnecessary. |
| readTimeoutMs | 1000 | Per-poll receive timeout. |
| defaultBatteryMv | 12000 | Battery-voltage fallback when the device can't measure. |
Debugging
EDIABASX_VERBOSE=1— TX/RX bytes, setpar decode, setconfig requests, regen waits.J2534_RAW_TRACE=1— raw USB-byte chunks from@emdzej/j2534-driver. Useful for telling "device sent nothing" apart from "device sent a frame our K-line assembler dropped".
See also
@emdzej/j2534-driver— the underlying SAE J2534 implementation.@emdzej/ediabasx-interface-serial— K+DCAN / raw FTDI alternative.