@flux-control/effect-teco-westinghouse-inverter
v0.2.0
Published
Effect First Typesafe communication library for the Teco WestingHouse A510 Inverter Family
Downloads
484
Readme
Effect-Teco-Westinghouse-Inverter
An Effect-TS service for Teco/Westinghouse A510 inverters that wraps @flux-control/effect-modbus-rs to manage the Modbus transport, map command and monitor registers, and apply typed schemas to all parameter groups (00–22).
For the complete API reference, see the GitHub Pages documentation.
TecoInverterService is a scoped Effect.Service that:
- Manages the transport — Opens RTU or ASCII connections via
@flux-control/effect-modbus-rsand caches a client per device ID. - Exposes operations — Typed command registers (start/stop, frequency, torque, analog/digital outputs) with read-modify-write semantics for bitfield registers.
- Exposes monitoring — Typed monitor registers (state, errors, frequency, current, voltage, etc.) that decode wire values into domain types.
- Maps parameters — Typed access to every A510 parameter (Groups 00–22) with proper scaling factors (×0.001, ×0.01, ×0.1, signed Int16, etc.) applied at encode/decode time.
This project is under active development. Its API may change before the 1.0 release.
Install
bun add @flux-control/effect-teco-westinghouse-inverterRequires effect, @flux-control/effect-modbus-rs, and @flux-control/modbus-schema as peer dependencies.
Quick start
import { Console, Effect, Layer } from 'effect';
import { TecoInverterService } from '@flux-control/effect-teco-westinghouse-inverter';
import { SerialTransportService } from '@flux-control/effect-modbus-rs';
const program = Effect.gen(function* () {
const inverter = yield* TecoInverterService;
const freq = yield* inverter.frequencyCommand(1).read();
yield* inverter.frequencyCommand(1).update(50.0);
});
program.pipe(
Effect.provide(
Layer.provideMerge(
TecoInverterService.Default(true),
SerialTransportService.fromRtu({ portPath: '/dev/ttyUSB0', baudRate: 19200 }),
),
),
Effect.scoped,
Effect.runPromise,
);Service
TecoInverterService is a scoped Effect.Service that manages a Modbus client pool per device. Provide it with Effect.provide alongside a transport layer (SerialTransportService from @flux-control/effect-modbus-rs).
Resilience
Retry and reconnection are owned by the transport, not by this service. Configure them where the transport layer is built and they apply to every inverter operation — there is no per-call wiring to do here:
SerialTransportService.fromRtu({
portPath: '/dev/ttyUSB0',
baudRate: 19200,
retry: RetryPolicies.serial(), // backoff + jitter, tuned for a serial bus
reconnect: {}, // supervised reconnect + circuit breaker
});With reconnect enabled, operations attempted while the link is down fail with ModbusCircuitOpenError rather than queueing onto a dead bus. It is a member of the ModbusError union, so it can surface from any read() or update() on this service — code that matches exhaustively on _tag should handle it. Defaults are unchanged: with neither option set, operations remain single-shot.
See the @flux-control/effect-modbus-rs docs for the full policy templates.
Command registers (write)
| Method | Register | Description |
| ----------------------------- | -------- | -------------------------------- |
| operationCommand(deviceId) | 0x2501 | Start/stop/reverse + fault reset |
| frequencyCommand(deviceId) | 0x2502 | Target output frequency (Hz) |
| torqueCommand(deviceId) | 0x2503 | Torque limit / command (%) |
| speedLimitCommand(deviceId) | 0x2504 | Speed limit (%) |
| analogOut1Command(deviceId) | 0x2505 | Analog output 1 (V) |
| analogOut2Command(deviceId) | 0x2506 | Analog output 2 (V) |
| digitalOutCommand(deviceId) | 0x2507 | Digital output terminals |
Monitor registers (read)
| Method | Register | Description |
| -------------------------------------- | -------- | -------------------------- |
| stateMonitor(deviceId) | 0x2520 | Operating state flags |
| errorDescriptionMonitor(deviceId) | 0x2521 | Fault code + description |
| digitalInStateMonitor(deviceId) | 0x2522 | Digital input states |
| frequencyCommandMonitor(deviceId) | 0x2523 | Active frequency command |
| outputFrequencyMonitor(deviceId) | 0x2524 | Actual output frequency |
| dcBusVoltageCommandMonitor(deviceId) | 0x2526 | DC bus voltage (V) |
| outputCurrentMonitor(deviceId) | 0x2527 | Output current (A) |
| warningDescriptionMonitor(deviceId) | 0x2528 | Warning code + description |
| digitalOutStateMonitor(deviceId) | 0x2529 | Digital output states |
| analogOut1Monitor(deviceId) | 0x252A | Analog output 1 voltage |
| analogOut2Monitor(deviceId) | 0x252B | Analog output 2 voltage |
| analogIn1Monitor(deviceId) | 0x252C | Analog input 1 (%) |
| analogIn2Monitor(deviceId) | 0x252D | Analog input 2 (%) |
| a510CheckMonitor(deviceId) | 0x252F | Drive series/model ID |
Parameter groups
Typed access to all Groups 00–22 via inverter.parameters.group##:
| Group | Name | Pages | | ----- | ----------------------------- | ----------- | | 00 | Basic Parameters | 4-19 – 4-22 | | 01 | Frequency Parameters | 4-37 – 4-38 | | 02 | Accel/Decel Parameters | 4-39 – 4-43 | | 03 | Multi-Function Input | 4-44 – 4-52 | | 04 | Multi-Function Digital Output | 4-53 – 4-59 | | 05 | Multi-Step/Speed | 4-60 – 4-66 | | 06 | VFD Protection | 4-67 – 4-71 | | 07 | Start/Stop | 4-72 – 4-74 | | 08 | Protection | 4-75 – 4-79 | | 09 | Communication | 4-80 | | 10 | PID Control | 4-81 – 4-84 | | 11 | Auxiliary Functions | 4-85 – 4-88 | | 12 | Monitoring | 4-62 – 4-67 | | 13 | Maintenance | 4-68 – 4-71 | | 14 | PLC Setting | 4-72 | | 15 | PLC Monitoring | 4-73 | | 16 | LCD Function | 4-74 – 4-77 | | 17 | Automatic Tuning | 4-78 – 4-79 | | 18 | Slip Compensation | 4-79 | | 19 | Wobble Frequency | 4-79 – 4-80 | | 20 | Speed Control | 4-80 – 4-82 | | 21 | Torque & Position Control | 4-82 – 4-85 | | 22 | PM Motor | 4-85 – 4-88 |
Each parameter callable returns { read(), update(value) } for a given deviceId.
Schema engine
The device-agnostic schema factories now live in the @flux-control/modbus-schema package:
makeParam(register, meta)— Simple UInt16 pass-throughmakeScaledParam(register, factor, meta)— Scaled value (e.g., 0.01 Hz)makeSignedScaledParam(register, factor, meta)— Signed scaled value using two's complement over UInt16 wiremakeEnumParam(register, labels, meta)— Labeled selection valuesmakeBitfieldParam(register, flagsClass, bitLayout, meta)— Boolean flags packed into a wordmakeLookupParam(register, labels, fallback, meta)— Decode-only lookup table with fallback
Each factory returns a ParamEntry with both Effect-native and synchronous decode/encode APIs. Parameter group files import ParamKind and ParamConfig directly from @flux-control/modbus-schema, and src/parameters/operations.ts hosts the inverter-specific ModbusError-coupled operation types.
Testing with mocks
Use SerialTransportService.makeMockTransport with TecoInverterService.mockDevice() — a built-in generator producing a full SlaveDeviceDefinition for the A510 with all registers defaulting to 0.
import { Console, Effect, Layer } from 'effect';
import { TecoInverterService } from '@flux-control/effect-teco-westinghouse-inverter';
import { SerialTransportService } from '@flux-control/effect-modbus-rs';
const program = Effect.gen(function* () {
const inverter = yield* TecoInverterService;
const freq = yield* inverter.frequencyCommand(1).read();
yield* inverter.frequencyCommand(1).update(50.0);
const freqAfter = yield* inverter.frequencyCommand(1).read();
yield* Console.log(`Frequency: ${freq} -> ${freqAfter}`);
});
const mockLayer = SerialTransportService.makeMockTransport([TecoInverterService.mockDevice(1)])({
portPath: '/dev/null',
baudRate: 9600,
});
program.pipe(
Effect.provide(Layer.provideMerge(TecoInverterService.Default('Rtu'), mockLayer)),
Effect.scoped,
Effect.runPromise,
);See examples/readAllRegistersMock.ts for a full walkthrough.
Overriding mock defaults
mockDevice() returns a standard SlaveDeviceDefinition. Override individual register defaults before passing to makeMockTransport:
const device = TecoInverterService.mockDevice(1);
const customRegisters = device.holdingRegisters.map((reg) => {
if (reg.address === 0x2501) return { address: reg.address, default: 5 }; // Running
if (reg.address === 0x2502) return { address: reg.address, default: 500 }; // 50.0 Hz
return reg;
});
const mockLayer = SerialTransportService.makeMockTransport([
{
...device,
holdingRegisters: customRegisters,
},
]);SlaveDeviceDefinition schema
| Property | Type | Description |
| ------------------ | ------------------------ | ---------------------------------------------- |
| unitId | number | Modbus slave/unit ID (required) |
| coils | { address, default }[] | Coil registers |
| discreteInputs | { address, default }[] | Discrete input registers |
| holdingRegisters | { address, default }[] | Holding registers (command + monitor + params) |
| inputRegisters | { address, default }[] | Input registers |
Register map
Command and monitor registers are TypeScript enums in src/Registers.ts:
COMMAND_REGISTERS— 0x2501–0x2507MONITOR_REGISTERS— 0x2520–0x252FGROUP_00_Basic_ParametersthroughGROUP_22_PM_Motor_Parameters— 0x0000–0x1623
Development
| Action | Command |
| ----------- | ---------------------------- |
| Install | bun install |
| Type-check | bun run typecheck |
| Test | bun test |
| Run example | bun run examples/<name>.ts |
Source layout
index.ts — Re-exports all public API
src/
Registers.ts — Modbus register address enums
TecoInverterService.ts — Scoped Effect.Service for A510 communication
errors.ts — Error utilities (readOnlyEncodeFailure)
schemas.ts — Command/monitor wire schemas + formatters
utils.ts — Bit helpers (bit)
parameters/
index.ts — Re-exports all parameter groups
operations.ts — Inverter-specific operation types that couple @flux-control/modbus-schema with @flux-control/effect-modbus-rs
group-00.ts … group-22.ts — Parameter configs per group
examples/
readOpsRegister.ts — Read/write operation command register
readAllRegisters.ts — Read all command + monitor registers
readAllRegistersMock.ts — Mock transport walkthrough
readGroup00Params.ts — Read all Group 00 parametersLicense
GPL-3.0