@oibus/opc-classic
v0.2.1
Published
Windows-only OPC Classic (DA/HDA) driver for OIBus. Spawns and multiplexes connections over a bundled .NET helper (OPC Foundation OpcNetApi/OpcComRcw DCOM interop, MIT) via a stdio JSON protocol.
Readme
@oibus/opc-classic
A Windows-only npm package: a small .NET console app wrapping the OPC Foundation's OPC Classic .NET
API and RCWs (OpcNetApi/OpcNetApi.Com/OpcComRcw, DCOM interop for OPC Classic DA + HDA), plus the TypeScript driver (src/index.ts) that
spawns and talks to it. A standalone driver for talking to OPC Classic DA/HDA servers from Node.js
on Windows — no dependency on any other project.
Instead of installing a separate, long-running Windows Service to reach an OPC Classic server, the calling process spawns this package's helper itself as a local child process on demand, talks to it over a small stdio JSON protocol, and can stop it again once it's no longer needed.
License & third-party notices
This repository's own source (Program.cs, src/) is licensed under the EUPL-1.2 — see
LICENSE. The published Windows binaries additionally embed, unmodified and not covered
by the EUPL:
- the OPC Foundation's OPC Classic .NET API and RCWs (
OpcNetApi,OpcNetApi.Com,OpcComRcw), built from the OPC Foundation's OPC-Classic-CoreComponents repository (pinned as thevendor/OPC-Classic-CoreComponentsgit submodule) and licensed under the OPC Foundation MIT License 1.00 (Copyright (c) 2005-2026, OPC Federation AISBL); - the .NET runtime (self-contained publish), licensed under the MIT License (Copyright (c) .NET Foundation and Contributors), with its own third-party notices.
The full license texts are in THIRD-PARTY-NOTICES.md, and each
runtimes/<rid>/ folder ships them next to the executable.
The native OPC Core Components (proxy/stub DLLs, OpcEnum) are not included: install them
separately on the target machine with the OPC Foundation's signed installer (or the one your OPC
server vendor supplies).
This project is not affiliated with or endorsed by the OPC Foundation.
Install
npm install @oibus/opc-classicWindows only (os: ["win32"] in package.json — npm will refuse to install it on any other
platform). Requires the OPC Core Components to be installed on the machine (see above), and a real
OPC Classic DA or HDA server reachable via DCOM (a local simulator like
the free Matrikon OPC Simulation server, or a real industrial OPC server) to actually connect to —
this package is a client/driver, not a server.
import { OpcConnection } from '@oibus/opc-classic';
const connection = await OpcConnection.connect('localhost', 'Matrikon.OPC.Simulation', 'da');
const values = await connection.read('2024-01-01T00:00:00Z', '2024-01-02T00:00:00Z', ['Random.Int1']);
await connection.disconnect();Framework: net10.0-windows
The helper targets net10.0-windows (.NET 10, LTS) and builds the OPC Foundation's OpcNetApi,
OpcNetApi.Com and OpcComRcw from source via ProjectReferences into the
vendor/OPC-Classic-CoreComponents submodule, which multi-target net10.0-windows among others.
The live testing described below against a Matrikon OPC Simulation server was done with an earlier
net9.0-windows build that used third-party NuGet repackagings (Quick.OpcNetApi & co.) of the
same OPC Foundation code; the TypeScript API and the stdio protocol are unchanged.
HDA needed one real fix along the way, found by testing, not by inspection: Matrikon.OPCHDA.Automation
(a different Matrikon product than the DA simulator) is registered as a 32-bit in-process
COM DLL (InprocServer32), which a 64-bit process cannot load directly — activation failed with
"Class not registered" until the same code was rebuilt as win-x86. That turned out to be a red
herring specific to that one Automation-wrapper product, though: the actual DA simulation server
(Matrikon.OPC.Simulation, OPCSim.exe) implements the HDA interfaces too, addressed via the
opchda:// URL scheme instead of opcda:// — connecting to Matrikon.OPC.Simulation in hda mode
works from a normal 64-bit process, with real historized reads confirmed live (raw values, and an
aggregate/resampling read that returned cleanly with no error, just no aggregated data for this
simulator's sparse test data — not a bug). Production OPC HDA servers are essentially always proper
out-of-process/remote DCOM servers, so the in-process-DLL bitness constraint found here is expected
to be rare in practice, not the default case.
Architecture
A single .NET helper process, spawned lazily on the first connect() call and stopped once the
last open connection disconnects, multiplexes any number of concurrent logical connections over one
stdio JSON protocol: each connection is tracked by a UUID id, and every request/response carries a
requestId so responses (which can legitimately arrive out of order across connections) get matched
back to the right caller. Commands on the same connection id are kept in strict arrival order via a
per-connection task chain on the .NET side, while commands on different connection ids run fully
concurrently. The process is drained (all in-flight work awaited) before it actually exits, so a
short-lived piped run can't lose a response to a race with stdin closing.
Each connection gets its own real Opc.Server object on the .NET side — a
ConcurrentDictionary<string, Opc.Server> keyed by connection id — since different connections can
genuinely target different hosts, servers, or DA/HDA modes; there's no single object shared across
every connection.
Connect is idempotent and self-healing on failure: it skips Connect() if already connected,
lazily creates the server object on first call per id, and on any connect failure disposes the
server and evicts it from the dictionary so the next attempt starts from a fresh DCOM activation
instead of retrying a dead COM object.
No auto-connect on read/browse — read/browse return "Not connected" if the id isn't in the
dictionary; a caller is expected to connect() explicitly first and to own its own reconnect policy
on failure, rather than relying on every read/browse silently reconnecting behind its back.
Works inside a pkg-bundled application too
If the calling application is itself bundled into a single executable with
pkg or @yao-pkg/pkg,
resolveOpcBinaryPath() handles that automatically — but it's worth knowing why, since it's not
obvious and was only found by actually building and running a pkg-bundled test app against this
package, not by inspection.
Inside a pkg bundle, paths resolved relative to __dirname point into pkg's virtual snapshot
filesystem (something like C:\snapshot\...). Reading such a path with fs works fine — pkg patches
fs to understand it — but child_process.spawn() does not: the OS process-creation call needs a
real file on the real filesystem, and a snapshot path isn't one. Confirmed directly: spawning the
helper straight from its snapshot path fails with ENOENT, even though fs.readFileSync on that
exact path succeeds. So when process.pkg is set (pkg's own marker for "running inside a bundle"),
resolveOpcBinaryPath() copies the embedded binary out to a real file under os.tmpdir() first and
returns that path instead — written via a per-process temp name and an atomic rename into place, so
two pkg-bundled instances of the calling application starting around the same time on the same
machine (a real scenario — e.g. two separate Windows services, both using this package) can't observe
or spawn a partially-written file.
The consuming application still needs to tell pkg to actually embed the runtime binaries in the
first place — they won't be picked up automatically. Add this package's runtimes folder to the
consuming application's own pkg.assets in its package.json:
"pkg": {
"assets": ["node_modules/@oibus/opc-classic/runtimes/**/*"]
}DA vs HDA
mode ('da' | 'hda') is a connect-time parameter — it picks Opc.Da.Server or Opc.Hda.Server
up front (opcda:///opchda:// URL scheme). Read dispatch is a runtime type check
(server is DAServer / is HDAServer) rather than re-checking mode, since the connection's own
server object already carries that information.
- DA read: one synchronous
server.Read(items)call — current/live values only, no paging (DA never returns a backlog). - HDA read: includes a manual pagination loop —
server.ReadRaw/ReadProcessedcan reportResultID.Hda.S_MOREDATA, so the helper resumes from the minimum "max time seen so far" across items that still have more data, releases items that are fully drained, and sleepsintervalReadDelayms between pages (a deliberate pacing choice, not a bug) — until nothing has more data.aggregate/resamplingmap to a 25-value aggregate ID / 7-value resample-interval-in-seconds table, with adefault: 0fallback for anything unrecognized, so an invalid or missing value degrades to "raw"/"no resampling" rather than throwing.
Browse (flat or recursive node listing, for both DA and HDA) is included too, confirmed working live, including recursive descent into branch nodes.
Protocol
Newline-delimited JSON on stdin/stdout, requests/responses correlated by requestId. ok only ever
appears on connect/disconnect; read/browse carry no ok at all — error's presence is the
only failure signal, values/nodes' presence the only success signal (one bulk call either
succeeds outright or fails outright, so there's nothing partial to report through a separate field).
{"requestId":"1","command":"connect","id":"<connection-uuid>","host":"localhost","serverName":"Matrikon.OPC.Simulation","mode":"da"}
{"requestId":"2","command":"read","id":"<connection-uuid>","startTime":"...","endTime":"...","items":["Random.Int1"]}
{"requestId":"3","command":"read","id":"<connection-uuid>","startTime":"...","endTime":"...","items":["Random.Int1"],"aggregate":"average","resampling":"1h","maxReadValues":3600,"intervalReadDelay":200}
{"requestId":"4","command":"browse","id":"<connection-uuid>","nodeId":"","recursive":false}
{"requestId":"5","command":"disconnect","id":"<connection-uuid>"}Responses:
{"requestId":"1","ok":true,"serverInfo":{"vendorInfo":"Matrikon Inc ...","productVersion":"1.9.8629","serverState":"running"}}
{"requestId":"2","values":[{"nodeId":"Random.Int1","timestamp":"2024-01-01T00:00:00.000Z","value":"73","quality":"0xC0"}]}
{"requestId":"4","nodes":[{"name":"Random","nodeId":"Random","isItem":false,"hasChildren":true,"nodes":[]}]}
{"requestId":"5","ok":true}items on a read command is a flat list of exact OPC item ids — no name on the wire; a caller
already knows which identifier it asked for, so mapping a raw nodeId back to its own naming is a
plain lookup on its side (OPC Classic items are always exact references, never a wildcard mask).
aggregate/resampling/maxReadValues/intervalReadDelay only matter for an HDA connection — a DA
connection ignores them entirely. serverInfo ({vendorInfo, productVersion, serverState}, off the
server's own GetStatus()) is gathered once on connect and carried on every OpcConnection.
Development
Requires Windows, the .NET 10 SDK, and the Node/npm versions pinned in package.json's engines
field. The OPC Foundation's .NET API/RCW sources come from a git submodule, so clone with
submodules (or initialize them in an existing checkout):
git clone --recurse-submodules https://github.com/OptimistikSAS/oibus-opc-classic.git
git submodule update --init # in an existing checkoutTo move to a newer upstream revision, check out the wanted commit in
vendor/OPC-Classic-CoreComponents and commit the updated submodule pointer (Renovate also proposes
submodule updates).
npm install # dev dependencies (typescript, tsx, @types/node)
npm run build # tsc -> dist/index.js + dist/index.d.ts
npm test # runs src/**/*.spec.ts against a fake child process (no real OPC server needed)
dotnet build # compiles the .NET helper for quick local testing (bin/Debug/net10.0-windows/...)dotnet build is enough to iterate on the .NET side quickly, but its output isn't in the layout
resolveOpcBinaryPath() expects at runtime (runtimes/<rid>/). Two ways to bridge that:
- Point
resolveOpcBinaryPath()at thedotnet buildoutput directly, for fast iteration:$env:OIBUS_OPC_CLASSIC_WINDOWS_BINARY = "$(pwd)\bin\Debug\net10.0-windows\OIBusOpcClassicWindows.exe" - Or build a real self-contained binary into
runtimes/<rid>/, matching what a published install actually ships (see Release below):npm run build:win-x64 # or build:win-x86, build:win-arm64, or build:runtimes for all three
To exercise the helper directly without going through the TS layer at all, pipe newline-delimited JSON commands at the built exe (see Protocol above).
Release
Releases are cut by pushing a v* tag (e.g. v0.1.1) — see .github/workflows/publish.yml. That
workflow, on a Windows runner:
npm run build:runtimes— runsbuild:win-x64/build:win-x86/build:win-arm64(each a plaindotnet publish -r <rid> --self-contained -p:PublishSingleFile=true -o runtimes/<rid>), so the same commands can be run locally to reproduce exactly what CI ships.npm run build(the TypeScript side).npm publish(scoped public package —publishConfig.accessinpackage.jsonis already set to"public", so no--accessflag is needed at publish time).
Bump version in package.json before tagging — npm will reject a publish that reuses an existing
version. dist/ and runtimes/ are gitignored (built fresh by CI at publish time, never committed).