@powston-com/electrical-symbols
v0.1.0
Published
React SVG electrical schematic symbols for Australian single line diagrams (IEC 60617 / AS 60617)
Maintainers
Readme
@powston/electrical-symbols
React SVG electrical schematic symbols for Australian single line diagrams.
Typed, composable components following IEC 60617 / AS 60617 conventions, designed for solar PV, battery storage, and embedded generation EWR submissions.
Install
npm install @powston/electrical-symbolsPeer dependencies: react >= 18
Quick Start
import {
SLDCanvas,
GridConnection,
EnergyMeter,
MainSwitch,
BusBar,
CircuitBreaker,
Isolator,
Inverter,
PVArray,
BatteryBank,
MENLink,
Load,
Connection,
InfoBox,
} from "@powston/electrical-symbols";
function MySLD() {
return (
<SLDCanvas width={720} height={540} showGrid={false}>
{/* Grid supply */}
<GridConnection x={200} y={30} networkName="ENERGEX LV NETWORK" supplyDesc="1Ø 230V 50Hz" />
{/* Meter */}
<Connection from={{ x: 200, y: 42 }} to={{ x: 200, y: 56 }} />
<EnergyMeter x={200} y={70} scheme="Net Energy" meterDesc="Import / Export" />
{/* Main switch */}
<Connection from={{ x: 200, y: 84 }} to={{ x: 200, y: 115 }} />
<MainSwitch x={200} y={135} rating="63A" />
<MENLink x={168} y={135} />
{/* Bus */}
<Connection from={{ x: 200, y: 155 }} to={{ x: 200, y: 195 }} />
<BusBar from={{ x: 100, y: 195 }} to={{ x: 420, y: 195 }} label="MAIN SWITCHBOARD" />
{/* Inverter branch */}
<Connection from={{ x: 200, y: 195 }} to={{ x: 200, y: 240 }} />
<Isolator x={200} y={250} label="AC Isolator" />
<Connection from={{ x: 200, y: 264 }} to={{ x: 200, y: 286 }} />
<Inverter x={200} y={310} make="Sungrow" model="SH10RS" rating="9.99 kW Single Phase" />
{/* DC bus from inverter */}
<Connection from={{ x: 200, y: 334 }} to={{ x: 200, y: 390 }} wireStyle="dc" />
<Connection from={{ x: 120, y: 390 }} to={{ x: 280, y: 390 }} wireStyle="dc" />
{/* PV array */}
<Connection from={{ x: 120, y: 390 }} to={{ x: 120, y: 410 }} wireStyle="dc" />
<Isolator x={120} y={420} dc />
<Connection from={{ x: 120, y: 434 }} to={{ x: 120, y: 450 }} wireStyle="dc" />
<PVArray x={120} y={468} capacity="20 kW" strings="4 MPPT" />
{/* Battery */}
<Connection from={{ x: 280, y: 390 }} to={{ x: 280, y: 410 }} wireStyle="dc" />
<Isolator x={280} y={420} dc />
<Connection from={{ x: 280, y: 434 }} to={{ x: 280, y: 450 }} wireStyle="dc" />
<BatteryBank x={280} y={468} make="Sungrow" model="2× SBR224" capacity="44.8 kWh" coupling="DC Coupled" voltage="378-511V DC" />
{/* Loads */}
<Connection from={{ x: 380, y: 195 }} to={{ x: 380, y: 248 }} />
<CircuitBreaker x={380} y={260} label="Load MCBs" />
<Connection from={{ x: 380, y: 272 }} to={{ x: 380, y: 286 }} />
<Load x={380} y={298} label="CONSUMER LOADS" />
{/* Info boxes */}
<InfoBox
x={480} y={215}
title="SYSTEM NOTES"
lines={[
"Export Limit: 5 kW (Partial)",
"PQRM: Volt-VAR / Volt-Watt",
"Metering: Net Energy",
]}
/>
<InfoBox
x={480} y={310}
title="COMPLIANCE"
lines={["AS/NZS 4777.1 & 4777.2", "AS/NZS 3000 | 5033 | 5139"]}
fill="#f0fdf4"
borderStroke="#16a34a"
titleColor="#166534"
textColor="#15803d"
/>
</SLDCanvas>
);
}Components
Grid & Supply
| Component | Description |
|-----------|-------------|
| GridConnection | Distribution network supply point |
| Transformer | Two-winding transformer |
Switching
| Component | Description |
|-----------|-------------|
| CircuitBreaker | MCB / MCCB |
| Isolator | AC or DC switch-disconnector |
| MainSwitch | Main supply switch |
| Fuse | Fuse element |
Metering
| Component | Description |
|-----------|-------------|
| EnergyMeter | kWh meter (import/export) |
| CTBlock | Current transformer |
Generation
| Component | Description |
|-----------|-------------|
| Inverter | Hybrid / string / micro inverter |
| PVArray | Photovoltaic array with sun rays |
| BatteryBank | Battery ESS with cell plates |
Protection
| Component | Description |
|-----------|-------------|
| RCD | RCD / RCBO |
| SurgeProtector | SPD / varistor |
| EarthSymbol | Protective earth |
| MENLink | Multiple Earthed Neutral link |
Wiring
| Component | Description |
|-----------|-------------|
| Connection | Wire between two points (AC/DC/earth/control styles) |
| BusBar | Heavy bus bar line with label |
| Junction | Connection node dot |
| Load | Generic consumer load (zigzag) |
Accessories
| Component | Description |
|-----------|-------------|
| DRMTerminal | Demand response mode terminal |
| InfoBox | Annotation / notes box |
Layout
| Component | Description |
|-----------|-------------|
| SLDCanvas | SVG canvas wrapper with optional dev grid |
Port System
Every symbol exposes named ports — connection points at fixed offsets from its origin. Use ports to calculate wire start/end coordinates:
import { resolvePorts, circuitBreakerMeta } from "@powston/electrical-symbols";
const ports = resolvePorts(circuitBreakerMeta.ports, 200, 300);
// → [{ name: "top", absX: 200, absY: 288 }, { name: "bottom", absX: 200, absY: 312 }]Or use the onPortsResolved callback on any symbol:
<CircuitBreaker
x={200}
y={300}
rating="32A"
onPortsResolved={(ports) => {
// ports[0].absX, ports[0].absY, etc.
}}
/>Wire Styles
The Connection component supports these wireStyle values:
| Style | Appearance | Use |
|-------|-----------|-----|
| "ac" | Solid line | AC circuits |
| "dc" | Long dash 6,3 | DC circuits |
| "earth" | Short dash 4,2 | Earth / protective |
| "control" | Fine dash, indigo | Control wiring |
| "communication" | Dotted, blue | Comms / data |
Symbol Registry
All component metadata is available in SYMBOL_REGISTRY for building palettes, tooling, or documentation:
import { SYMBOL_REGISTRY } from "@powston/electrical-symbols";
SYMBOL_REGISTRY.forEach((meta) => {
console.log(meta.id, meta.category, meta.ports);
});Standards Reference
Symbols are based on:
- IEC 60617 / AS 60617 — Graphical symbols for diagrams
- AS/NZS 3000 — Wiring Rules
- AS/NZS 4777.1 & 4777.2 — Grid connection of energy systems via inverters
- AS/NZS 5033 — Installation and safety requirements for PV arrays
- AS/NZS 5139 — Electrical installations - Safety of battery systems
License
MIT © Powston