@shuji-bonji/s1000d-reader-mcp
v0.7.1
Published
MCP server that reads S1000D® data modules and publication modules as structure (sections, steps, warnings, figures, references), evaluates applicability for a product, and always reports how far the document was verified. Not affiliated with ASD.
Maintainers
Readme
@shuji-bonji/s1000d-reader-mcp
English | 日本語
An MCP server that lets an LLM read S1000D® data modules and publication modules as structure rather than as XML. It returns the heading hierarchy, numbered steps, warnings, cautions and notes, illustrations (ICN), tables and the titles of reference targets intact, and the server evaluates which product the content applies to (applicability) and passes on only the result. Every response carries how far the document has been verified (verification).
[!IMPORTANT] This is a personal project and is not affiliated with ASD (Aerospace, Security and Defence Industries Association of Europe). S1000D® is a registered trademark of ASD. The S1000D specification, XML schemas, default BREX and official samples are not included in any package or repository, because their terms of use do not grant redistribution. Obtain them from s1000d.org and point the
S1000D_SPEC_DIRenvironment variable at the extracted folder.
What it does
| Tool | Description |
|---|---|
| list_data_modules | Lists the data modules in a CSDB (and, on request, PMs, DMLs, DDNs, IMFs and UPFs) with their DMC, title, issue, language, schema name and applicability display text. Filters by model identification code, system code, information code, schema name and title text. A DML or DDN row also carries its code, issue date, entry or item count and a reconciliation summary against the CSDB (found / issue-mismatch / not-found / not-checked; for a DML also how many DMs and PMs it does not list). The per-entry result comes from reconcile_dml in s1000d-verify-mcp |
| read_data_module | Reads one data module as structure: the identification and status section, the body tree (sections, paragraphs, lists, tables, illustrations, warnings, numbered steps and requirements, process branches, fault isolation questions and answers), references (with titles) and the verification status. Pass product to mark each block applicable / notApplicable / undetermined. With section: "outline" it returns only headings, step numbers, the first sentence and the size of each subtree (nodes, characters, warnings), so a large data module can be surveyed before its body is read |
| read_publication_module | Reads a publication module as a table of contents: the pmEntry tree and the resolved target of each dmRef / pmRef (file, title, issue) |
| resolve_reference | Resolves a DMC, PMC or ICN to a file in the CSDB. For an ICN it also returns the DOCTYPE declaration of the referencing DM (file name and NOTATION) |
| describe_applicability | Returns the applicability vocabulary: product attributes from the ACT (id, name, enumerations, identifiers), conditions from the CCT, products from the PCT (values that can be passed to product as they are), the applic statements of the DM (id and display text), and attributes to which the PCT assigns no value. It evaluates nothing |
| read_icn_metadata | Reads an ICN metadata file (IMF): ICN, issue, title, keywords, security classification and a list of the items in the status section |
Reading applicability
| State | Meaning |
|---|---|
| applicable | Applies to the product you passed |
| notApplicable | Does not apply. omitNotApplicable: true leaves it out of the body |
| undetermined | Cannot be evaluated. reason says why (the name of an attribute the product lacks, product not given, an applicIdentValue missing from the applicability repository). This does not mean "does not apply" |
The server does not return assert / evaluate expressions. Look up the attributes and values you need with describe_applicability and pass them to product in the form { "attributes": { "model": "…" }, "conditions": { … } }.
Verification status (verification)
By default the server runs XSD validation only (verify: "schema"). verify: "full" also checks against the BREX (Business Rules Exchange) chain and resolves references; verify: "none" skips them. A skipped step is reported as not-run, and a missing XSD as schema-not-found; neither is valid. In a document that violates the XSD, elements may be in positions that differ from the specification, so treat the reading of the body with suspicion as well.
Security classification (securityClassification) and size (size)
Every read_data_module and read_publication_module response starts with securityClassification: dataModule (the value in the identification and status section) and inContent (the number of body elements per value). The server does not interpret the values (S1000D leaves their meaning to the project). An agent can decide how to handle the content before quoting it. The body carries size (nodes, characters, count per kind, number of warnings) so the amount to read can be estimated.
What it does not do
[!WARNING]
- It does not summarise or translate. Its job is to return the material a summary needs (headings, step numbers, warning types, reference targets) without dropping anything.
- It does not judge conformance to S1000D. Read the details of XSD and BREX violations with
s1000d-verify-mcp, and the explanation of BREX rules withs1000d-brex-mcp.- The body is structured for 5 types only:
descript/proced/process/fault/pm. Other types returncontent.structured: falseand only the identification and status section. Unknown elements are kept askind: "unknown"with their text only and counted incontent.unknownElements.
Configuration
| Environment variable | Description |
|---|---|
| S1000D_SPEC_DIR | The folder where you extracted the S1000D distribution you obtained. The server looks for the XSD (xml_schema_flat/) and the default BREX under it. It does not use the copies of the XSD inside the data dictionary |
| S1000D_CSDB_DIR | The folder that holds the project's data modules. Several folders can be given, separated by : (; on Windows). Reading by DMC, reference targets, the ACT, CCT and PCT, and the applicability repository are looked up here |
Folders can also be added with the tool argument csdbDirs.
Config file (when environment variables are not passed, as with plugins in Claude Desktop)
If S1000D_SPEC_DIR / S1000D_CSDB_DIR are not set, the server reads the config file ~/.config/s1000d-stack/config.json (under XDG_CONFIG_HOME if it is set; S1000D_CONFIG changes the location). Claude Desktop does not pass environment variables to servers installed as plugins, and does not substitute ${VAR} written in the plugin's env. When you install the server as a plugin, write the folders here.
{
"specDir": "/path/to/s1000d/issue-7",
"csdbDirs": ["/path/to/your/csdb"]
}Environment variables take precedence when they are set. Paths that start with ~/ are accepted. The config file is read again on every call, so the server does not need to be restarted after you edit it.
Example configuration for Claude Desktop / Claude Code
{
"mcpServers": {
"s1000d-reader": {
"command": "npx",
"args": ["-y", "@shuji-bonji/s1000d-reader-mcp"],
"env": {
"S1000D_SPEC_DIR": "/path/to/s1000d/issue-7",
"S1000D_CSDB_DIR": "/path/to/your/csdb"
}
}
}
}Running over HTTP (embedding in a product)
The default is stdio. With --http the server starts over Streamable HTTP, so a CSDB product's server or a web application can call it over HTTP (the embedding foundation of stage 2.5).
npx -y @shuji-bonji/s1000d-reader-mcp --http # http://127.0.0.1:3000/mcp
npx -y @shuji-bonji/s1000d-reader-mcp --http --port 3101 --path /reader| Argument | Default | Meaning |
|---|---|---|
| --host | 127.0.0.1 | Address to bind to |
| --port | 3000 | Port; 0 picks a free port |
| --path | /mcp | Path of the MCP endpoint. GET /healthz returns the name and version |
| --allowed-host | (see below) | Host names allowed in the Host header; comma-separated or repeated |
| --allowed-origin | (see below) | Host names allowed in the Origin header |
When --host is a loopback address (127.0.0.1 / ::1 / localhost), Host and Origin are limited to localhost names (DNS rebinding protection). When bound to any other address they are not checked, so put the server behind the product's reverse proxy or authentication. Authentication, authorization and multi-tenancy are not part of this server. Environment variables and the config file work the same as with stdio.
How it works
All reading, evaluation and validation code lives in the shared library @shuji-bonji/s1000d-core; this server holds only the interpretation of arguments and the shape of the responses. The verification status is built with the same function as s1000d-verify-mcp, so the results of the two servers agree.
Development
npm install
npm test # runs on self-made test data only
npm run test:spec # uses the distribution you obtained (location given by S1000D_SPEC_DIR; default ../../specs/s1000d/issue-7)
npm run build && S1000D_SPEC_DIR=/path/to/issue-7 S1000D_CSDB_DIR=/path/to/csdb npm start # start over stdioLicense
MIT. S1000D® is a registered trademark of ASD. This software is not affiliated with ASD and does not include the specification, schemas or official samples.
