@totemsdk/edge-modbus
v0.1.0
Published
Edge runtime adapter for Modbus — PLCs, RTUs, industrial sensors over serial/TCP
Maintainers
Readme
@totemsdk/edge-modbus
Edge runtime adapter for Modbus — PLCs, RTUs, industrial sensors over serial/TCP.
Install
npm install @totemsdk/edge-modbusDesign
This package does not import modbus-serial, net, or serialport. All network/serial behaviour is injected via ModbusTransportPort. You provide the transport; the package handles framing, polling, and proof generation.
Quick start
import { createEdgeRuntime, createEdgeDevice, createCapabilitySet } from '@totemsdk/edge';
import { createModbusGateway, createModbusSensorBridge } from '@totemsdk/edge-modbus';
import type { ModbusTransportPort } from '@totemsdk/edge-modbus';
// 1. Implement ModbusTransportPort for your environment
const transport: ModbusTransportPort = {
async connect() { /* open TCP socket or serial port */ },
async disconnect() { /* close */ },
async sendFrame(frame) { /* send raw Modbus frame, return response */ },
onFrame(handler) { /* register inbound frame handler */ return () => {}; },
onError(handler) { /* register error handler */ return () => {}; },
};
// 2. Wire into Edge runtime
const runtime = createEdgeRuntime({
deviceId: 'plc-gateway-01',
capabilities: createCapabilitySet(['transport:modbus', 'proof:create']),
ports: { /* proof port from edge-adapters */ },
});
// 3. Create gateway
const gateway = createModbusGateway({ runtime, transport });
await gateway.start();
// 4. Read registers
const result = await gateway.readRegisters(1, 0, 10);
console.log(result.data?.values); // [123, 456, ...]
// 5. Or use the sensor bridge for automated polling + proof generation
const bridge = createModbusSensorBridge({
runtime,
transport,
gateway,
bindings: [
{ sensorId: 'temp-zone-1', unitId: 1, functionCode: 3, address: 0, count: 2, intervalMs: 5000, dataType: 'temperature', unit: '°C' },
{ sensorId: 'pump-status', unitId: 2, functionCode: 1, address: 0, count: 1, intervalMs: 1000, dataType: 'coil' },
],
});
await bridge.start();Transport port
You must implement ModbusTransportPort:
| Method | Description |
|--------|-------------|
| connect() | Open TCP socket (port 502) or serial port |
| disconnect() | Close the connection |
| sendFrame(frame) | Send raw Modbus frame bytes, return response bytes |
| onFrame(handler) | Register handler for unsolicited/inbound frames |
| onError(handler) | Register handler for connection errors |
Supported function codes
| Code | Name | Gateway method |
|------|------|---------------|
| 1 | Read Coils | readCoils(unitId, address, count) |
| 3 | Read Holding Registers | readRegisters(unitId, address, count) |
| 4 | Read Input Registers | Via sensor bridge |
Capabilities
transport:modbus— required for Modbus transport
License
MIT