@ya-modbus/emulator
v0.12.0
Published
Software Modbus device emulator for testing drivers without physical hardware
Maintainers
Readme
@ya-modbus/emulator
Software Modbus device emulator for testing device drivers without physical hardware.
Features
- Realistic device simulation: Mimic actual device constraints and timing characteristics
- Test acceleration: Enable fast, deterministic testing without hardware
- Edge case coverage: Simulate error conditions and edge cases
- Multiple transports: TCP, RTU (virtual/real serial ports), and in-memory
- Custom function codes: Support vendor-specific Modbus extensions
Installation
npm install @ya-modbus/emulatorQuick Start
Memory Transport (fastest for unit tests)
import { ModbusEmulator } from '@ya-modbus/emulator'
// Create emulator with in-memory transport
const emulator = new ModbusEmulator({
transport: 'memory',
})
// Add a device
emulator.addDevice({
slaveId: 1,
registers: {
holding: {
0: 230, // Voltage * 10 = 23.0V
1: 52, // Current * 10 = 5.2A
},
},
})
// Start emulator
await emulator.start()
// Use with your driver tests
// ...
// Stop emulator
await emulator.stop()TCP Transport (network)
import { ModbusEmulator } from '@ya-modbus/emulator'
// Create emulator with TCP transport
const emulator = new ModbusEmulator({
transport: 'tcp',
host: '0.0.0.0', // Listen on all interfaces
port: 502, // Standard Modbus TCP port
})
// Add devices
emulator.addDevice({
slaveId: 1,
registers: {
holding: { 0: 230, 1: 52 },
},
})
emulator.addDevice({
slaveId: 2,
registers: {
holding: { 0: 500, 1: 100 },
},
})
// Start emulator
await emulator.start()
// Use with your driver tests (clients connect to localhost:502)
// ...
// Stop emulator
await emulator.stop()RTU Transport (serial port)
import { ModbusEmulator } from '@ya-modbus/emulator'
// Create emulator with RTU transport
const emulator = new ModbusEmulator({
transport: 'rtu',
port: '/dev/ttyUSB0', // or 'COM3' on Windows
baudRate: 9600,
parity: 'none',
dataBits: 8,
stopBits: 1,
// lock: true, // Enable exclusive port locking (default)
})
// Add devices
emulator.addDevice({
slaveId: 1,
registers: {
holding: { 0: 230, 1: 52 },
},
})
emulator.addDevice({
slaveId: 2,
registers: {
holding: { 0: 500, 1: 100 },
},
})
// Start emulator
await emulator.start()
// Use with your driver tests
// ...
// Stop emulator
await emulator.stop()CLI Usage
The emulator can be used from the command line for quick testing:
Basic Usage
# Start with config file
ya-modbus-emulator --config config.yaml
# Or specify parameters directly
ya-modbus-emulator --transport rtu --port /dev/ttyUSB0 --slave-id 1Command Line Options
Options:
-c, --config <file> Configuration file (YAML or JSON)
-t, --transport <type> Transport type: tcp|rtu|memory
-p, --port <port> TCP port number or serial port path
-H, --host <host> TCP host address (default: 0.0.0.0)
-b, --baud-rate <rate> Serial baud rate (default: 9600)
--parity <type> Serial parity: none|even|odd (default: none)
--no-lock Disable serial port locking (enabled by default)
-s, --slave-id <id> Slave ID (required if no config file)
-v, --verbose Enable verbose logging
-q, --quiet Suppress all output except errors
-V, --version output the version number
-h, --help display help for commandVerbose Logging
Enable verbose logging to see detailed Modbus operations for debugging and testing:
CLI:
# With config file
ya-modbus-emulator --config config.yaml --verbose
# Or directly
ya-modbus-emulator --transport rtu --port /dev/ttyUSB0 --slave-id 1 --verboseProgrammatic:
const emulator = new ModbusEmulator({
transport: 'memory',
verbose: true,
})Output Format:
[VERBOSE] READ slave=1 func=0x03 addr=0x0000 count=2 values=[0x1234, 0x5678]
[VERBOSE] WRITE slave=1 func=0x06 addr=0x0005 count=1 values=[0x9ABC]
[VERBOSE] WRITE slave=2 func=0x10 addr=0x0010 count=3 values=[0xAABB, 0xCCDD, 0xEEFF]Each log entry includes:
- Operation type: READ or WRITE
- Slave ID: Which device handled the request
- Function code: Modbus function (0x03=Read Holding, 0x04=Read Input, 0x06=Write Single, 0x10=Write Multiple)
- Starting address: Register address in hexadecimal
- Register count: Number of registers accessed
- Values: Register values in hexadecimal
Verbose logging is useful for:
- E2E testing: Verify exact data flow in integration tests
- Driver development: Debug communication with emulated devices
- Protocol validation: Ensure correct Modbus message formatting
Configuration Files
Create a YAML or JSON configuration file to define devices and behaviors:
Basic TCP Example (basic-tcp.yaml):
transport:
type: tcp
host: 0.0.0.0
port: 502
devices:
- slaveId: 1
registers:
holding:
0: 230 # Voltage * 10 = 23.0V
1: 52 # Current * 10 = 5.2ABasic RTU Example (basic-rtu.yaml):
transport:
type: rtu
port: /dev/ttyUSB0
baudRate: 9600
parity: none
devices:
- slaveId: 1
registers:
holding:
0: 230 # Voltage * 10 = 23.0V
1: 52 # Current * 10 = 5.2APower Meter with Timing (power-meter.yaml):
transport:
type: rtu
port: /dev/ttyUSB0
devices:
- slaveId: 1
registers:
holding:
0: 2300 # Voltage * 10 = 230.0V
1: 52 # Current * 10 = 5.2A
2: 11960 # Power = 1196W
timing:
pollingInterval: 10
commandDetectionDelay: [3, 8]
processingDelay: [2, 5]
perRegisterDelay: 0.1Multiple Devices (multi-device.yaml):
transport:
type: rtu
port: /dev/ttyUSB0
devices:
- slaveId: 1
registers:
holding: { 0: 100, 1: 200 }
- slaveId: 2
registers:
holding: { 0: 300, 1: 400 }
- slaveId: 3
registers:
holding: { 0: 500, 1: 600 }See examples/config-files/ for more examples.
Testing with Virtual Serial Ports
For testing without physical hardware, create virtual serial port pairs:
Linux/macOS (using socat):
# Terminal 1: Create virtual serial port pair
socat -d -d pty,raw,echo=0 pty,raw,echo=0
# Note the output: /dev/pts/3 <-> /dev/pts/4
# Terminal 2: Start emulator on first port (disable locking for virtual ports)
ya-modbus-emulator --transport rtu --port /dev/pts/3 --slave-id 1 --no-lock
# Terminal 3: Run your driver tests against second port
node test-driver.js --port /dev/pts/4Note: Virtual serial ports created by
socatdon't properly support exclusive locking. Use--no-lockflag or setlock: falsein config files when using virtual ports.
Windows (using com0com):
- Install com0com
- Create a pair: COM10 <-> COM11
- Start emulator:
ya-modbus-emulator --transport rtu --port COM10 --slave-id 1 --no-lock - Run tests:
node test-driver.js --port COM11
Troubleshooting:
If you encounter Error: Resource temporarily unavailable Cannot lock port:
- Add
--no-lockflag to the CLI command, OR - Set
lock: falsein your config file's transport section
This error occurs with virtual serial ports (socat PTYs, com0com) that don't properly reset exclusive locks. For production use with real serial hardware, keep locking enabled (default).
See examples/virtual-serial-test.md for detailed virtual serial port testing guide.
Configuration
Timing Behaviors
Simulate realistic device response times:
emulator.addDevice({
slaveId: 1,
timing: {
pollingInterval: 10, // Device checks for commands every 10ms
commandDetectionDelay: [3, 8], // 3-8ms to notice command
processingDelay: [2, 5], // 2-5ms to process
perRegisterDelay: 0.1, // 0.1ms per register
},
})Register Constraints
🚧 Planned for v0.2.0: Define forbidden ranges and batch size limits
// Coming in v0.2.0
emulator.addDevice({
slaveId: 1,
constraints: {
maxReadRegisters: 80,
maxWriteRegisters: 50,
forbiddenReadRanges: [{ type: 'holding', start: 100, end: 199, reason: 'Protected' }],
},
})Error Simulation
🚧 Planned for v0.2.0: Inject errors for testing error handling
// Coming in v0.2.0
emulator.addDevice({
slaveId: 1,
errors: {
timeoutProbability: 0.05, // 5% timeout rate
crcErrorProbability: 0.01, // 1% CRC error rate
},
})License
GPL-3.0-or-later