homebridge-myhome-unik
v0.4.11
Published
MyHome Legrand plugin for homebridge
Maintainers
Readme
homebridge-myhome-unik
Homebridge platform plugin for Legrand MyHome / BTicino home automation gateways. Exposes lights, blinds, thermostats, scenarios, dry contacts, and energy meters to Apple HomeKit via the Homebridge Dynamic Platform API.
Requirements
- Homebridge ≥ 2.0
- Node.js ≥ 18
- A Legrand MyHome gateway (F452, F454, F455, MH200, …) reachable on the local network over TCP port 20000
Installation
npm install -g homebridge-myhome-unikOr install via the Homebridge UI plugin search.
Device discovery
The plugin includes a discovery tool that connects to the gateway and generates a draft config fragment:
npm run scan -- 192.168.1.35
# With password and custom address range:
npm run scan -- 192.168.1.35 20000 12345 --max-addr 50
# Show raw CONFIG-scan packets for debugging:
npm run scan -- 192.168.1.35 20000 12345 --verboseThe tool runs two phases:
- CONFIG scan — queries the gateway's internal device list (F454/F455 only)
- STATUS scan — probes each address (1..N) for all device types; works on all gateways
The output is a JSON fragment you paste into your Homebridge platform config, then adjust:
- Rename entries to meaningful names
- Set
time(travel seconds) for blinds - Set
timeSlat/slatPercentfor venetian blinds - Verify
zonefor thermostats - Add
"dimmer": truefor dimmer-capable lights - Add scenarios manually (they have no detectable status)
Configuration
Add a platform block to your Homebridge config.json:
{
"platform": "MyHome",
"name": "MyHome",
"host": "192.168.1.35",
"port": 20000,
"password": "12345",
"lights": [...],
"blinds": [...],
"thermostats": [...],
"scenarios": [...],
"contacts": [...],
"energies": [...]
}Platform options
| Key | Type | Default | Description |
|-----|------|---------|-------------|
| host | string | — | Required. IP address or hostname of the gateway |
| port | integer | 20000 | TCP port |
| password | string | "" | Numeric password (leave empty if none) |
| maxConcurrent | integer | auto | Max simultaneous TCP command connections (1–10). If omitted the plugin queries the gateway model (*#13**15##) at startup and sets the limit automatically: F454 → 4, F452/F452V/MH200 → 3, others/unknown → 2 |
| autoDiscover | boolean | false | Scan the gateway at startup for devices not yet in config and register them as placeholder accessories (Light 5, Blind 3, etc.). Add the discovered devices to config.json and restart to make them permanent — the placeholder is then automatically removed. |
| autoDiscoverMaxAddr | integer | 20 | Maximum address (1..N) probed per WHO type during auto-discovery. Higher values find more devices but lengthen the startup scan. Range 1–99. |
Accessory arrays
lights
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | OWN WHERE address |
| name | string | no | Display name in HomeKit |
| dimmer | boolean | no | Enable brightness control (levels 2–10). When a light is triggered by a gateway scenario or automation rule, the gateway sends an extended packet (*1*1000#X*WHERE##) that is handled transparently. |
| where | string | no | Custom raw OWN WHERE address for special relay configurations (e.g. "68#4#01" for group/sub-unit relays). Defaults to String(id). |
blinds
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | OWN WHERE address |
| name | string | no | Display name |
| time | integer | yes | Seconds for full travel (up or down) |
| timeSlat | integer | no | Extra seconds for slat rotation (venetian blinds only) |
| slatPercent | integer | no | Position % below which slat rotation occurs (venetian blinds only) |
| calibrateOnStart | boolean | no | Default true. When true, the blind moves fully down on first Homebridge start to establish a known position (0%). Set to false to restore the last cached position from accessory.context.blindPosition without moving the blind — useful if you don't want blinds to move on every Homebridge restart. The position is automatically cached on every STOP and at every 10% boundary during movement. Manual (wall-switch) movements that reach a physical end-stop automatically recalibrate the position to 0% or 100%, cancelling any timer drift accumulated over time. |
thermostats
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | Zone probe address |
| zone | integer | yes | Central unit zone number |
| name | string | no | Display name |
Supports HEAT, COOL, OFF and AUTO modes. The target temperature characteristic is exposed to HomeKit in the range 5°C..30°C; values reported by the gateway outside this range (e.g. 0 when a zone is OFF) are clamped to avoid HAP warnings. A linked TemperatureSensor service is added so the Home app can graph temperature history.
scenarios
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | Scenario number (WHO=0) |
| name | string | no | Display name |
Scenarios are exposed as an auto-reset switch — pressing it triggers the scenario, then resets to off after 500 ms. Prefer gateway scenarios over HomeKit scenes when controlling many devices at once (single command vs. one command per device).
Note: the historical
asButtonoption (which exposed the scenario as aStatelessProgrammableSwitch) was removed in 0.4.7. A stateless programmable switch is emit-only in HomeKit — it could not receive taps from the Home app, soasButton: truesilently disabled scenario activation. If you hadasButton: truein your config, simply remove that key; the previously-registered SPS service is cleaned up automatically at next startup.
contacts
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | Auxiliary/dry contact address (WHO=9) |
| name | string | no | Display name |
| sensorType | string | no | One of contact (default), motion, occupancy, leak, smoke, co. Selects the HomeKit service used to display the dry contact. |
Read-only contact sensor. For motion/occupancy/leak/smoke/co types: contact CLOSED = safe/idle, contact OPEN = triggered/alarm. Changing sensorType at runtime removes the old service.
energies
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | Energy meter address (WHO=18) |
| name | string | no | Display name |
| asOutlet | boolean | no | Expose as Outlet with Eve Consumption characteristic instead of LightSensor (default false). |
Default mode: light sensor (watts reported as lux). With asOutlet: true the meter is exposed as an Outlet whose In Use reflects power draw, plus the Eve custom Consumption characteristic for proper Eve.app energy graphing. Polls every 30 s. Changing this flag at runtime removes the old service.
doors (door entry / video door — WHO=7)
| Key | Type | Required | Description |
|-----|------|----------|-------------|
| id | integer | yes | Door entry / video door address (WHO=7) |
| name | string | no | Display name |
| openCommand | string | no | OWN command to send when the lock is opened (default *7*19*<id>##) |
| doorbell | boolean | no | Add a linked Doorbell service that fires SINGLE_PRESS on incoming WHO=7 packets matching the address |
Exposed as LockMechanism. Setting the lock to UNSECURED sends the open command; the lock auto-resets to SECURED after 3 s (the relay is momentary). With doorbell: true, an incoming bus packet (e.g. an intercom button press) fires a HomeKit doorbell event for automation.
Known Limitations
- UUID stability: HomeKit accessory UUIDs are derived from
myhome-${type}-${id}. Changing thetypeof a config entry (e.g. moving anidfromlightstocontacts) generates a new UUID, unregisters the old accessory, and registers a new one. HomeKit automations referencing the old accessory will need to be recreated. - Tile flips: When you toggle
asOutletorsensorType, the plugin removes the old service from the accessory at next startup. HomeKit automations bound to the old service will need to be recreated.
Example configuration
{
"platform": "MyHome",
"name": "MyHome",
"host": "192.168.1.35",
"password": "12345",
"lights": [
{ "id": 11, "name": "Living room" },
{ "id": 12, "name": "Kitchen", "dimmer": true }
],
"blinds": [
{ "id": 21, "name": "Living room blind", "time": 25 },
{ "id": 22, "name": "Bedroom venetian", "time": 20, "timeSlat": 3, "slatPercent": 10 }
],
"thermostats": [
{ "id": 1, "zone": 1, "name": "Living room thermostat" }
],
"scenarios": [
{ "id": 1, "name": "Good night" },
{ "id": 2, "name": "All off" }
],
"contacts": [
{ "id": 1, "name": "Front door" }
],
"energies": [
{ "id": 1, "name": "Main meter" }
]
}How it works
The plugin opens two types of TCP connections to the gateway:
- Monitor connection (persistent): receives all state-change events pushed by the gateway in real time.
- Command connections (short-lived): one connection per command, queued with a configurable concurrency limit. The gateway model is queried at startup to set the optimal limit automatically.
Authentication uses the OpenWebNet HMAC-style nonce/response mechanism (calcPass).
The monitor connection is watched by a keep-alive probe (*#13**15##). If the probe fails three times consecutively the connection is re-established with exponential back-off (up to 5 minutes between attempts).