homebridge-pima-force
v0.1.23
Published
Homebridge plugin for the Pima FORCE alarm panel via local CMS protocol over TCP/JSON
Maintainers
Readme
homebridge-pima-force
Homebridge plugin for the PIMA FORCE alarm system. Exposes each partition as a HomeKit Security System, each configured zone as a contact / motion / leak / smoke sensor, and the external siren as a switch you can flip off to mute an active alarm. Zones can optionally get a bypass switch — the only way to silence a 24-hour detector, e.g. so cooking doesn't trip the kitchen smoke alarm.
Requirements
Check with node -v and homebridge -V.
Installation
The plugin can be installed and configured via the Homebridge Config UI X — search for homebridge-pima-force, install, and use the schema-driven settings page.
Manual install:
- Install Homebridge:
sudo npm install -g homebridge --unsafe-perm - Install this plugin:
sudo npm install -g homebridge-pima-force - Configure the panel side (next section) so it dials in to your Homebridge host.
- Add a platform block to your Homebridge
config.jsonlisting only your partitions and their user codes (see "First-run / zone discovery" below). Do not enumerate zones manually — the plugin will populate them on first connect. - Restart Homebridge. After the panel dials in, the plugin auto-discovers every zone, writes them into
config.json, and registers each as a HomeKit sensor on the spot — they appear in the Home app immediately.
* Install from git: sudo npm install -g git+https://github.com/electricmonk/homebridge-pima-force.git
First-run / zone discovery
The intended setup flow is partition-only configuration: you list the partitions and the user code authorized to arm/disarm each, and the plugin handles zones automatically.
- Configure the panel-side CMS path (next section) — this is what makes the panel dial in to the plugin's TCP listener.
- Add the platform block to
config.jsonwithaccount,port, and one entry per partition (id,name,userCode). Skipzones. (See "Basic config" below.) - Start Homebridge. When the panel connects, the plugin queries it for the installed zone count and zone names, then appends each new zone to
config.jsonas{ "zone": N, "name": "<from panel>", "type": "contact" }and registers each as a HomeKit sensor in-process — so they appear in the Home app immediately, without needing a Homebridge restart. - In the plugin settings UI (or directly in
config.json), adjust each zone'stypeto one ofcontact/motion/leak/smoke. Type changes take effect on the next Homebridge restart — Homebridge doesn't reload the plugin's in-memory config whenconfig.jsonchanges. Zone names already came from the panel — usually no need to rename. - Auto-discovery is append-only. Names you've changed are never overwritten, types you've set are never reverted, and zones the panel temporarily stops reporting are not removed (a sensor going offline shouldn't drop the HomeKit accessory). Adding a new sensor to the panel later re-triggers discovery on the next plugin restart, and the new zone is appended + registered.
If your panel returns Hebrew names that arrive garbled in HomeKit (? characters), set encoding (default windows-1255) to whatever code page your panel uses — see the parameters table below.
Panel-side setup (important — the panel dials out to this plugin)
The PIMA FORCE alarm is the TCP client of this plugin's listener. You must configure a CMS path on the panel pointing at the Homebridge host:
- At the keypad, hold Quit → enter your Installer Code.
- System Configuration → CMS & Communication → Monitoring Station → CMS2 (or CMS3 — leave any existing CMS1 you may have for an alarm-monitoring service alone).
- Event Reporting — on the 4th screen, set Zone/Output Toggle = ON.
- Comm.Paths → Network (Ethernet):
- Account ID: any decimal you want (e.g.
1234). Must matchaccountin the plugin config. - IP/URL 1: the IP of your Homebridge host.
- Port: the same port you use in the plugin config (default
7780).
- Account ID: any decimal you want (e.g.
- On the 2nd screen of Network (Ethernet), set Protocol = JSON.
- General Settings → Remote Disarm = ON (allows the plugin to disarm).
The panel can have up to three CMS paths active at once, so you can run this plugin alongside an existing monitoring company or Control4 driver without disturbing them.
Config file
Basic config (what you write yourself)
The minimum the plugin needs to start. After the panel dials in, the zones array is auto-populated.
"platforms": [
{
"platform": "PimaForce",
"name": "Pima FORCE",
"port": 7780,
"account": 1234,
"partitions": [
{
"id": 1,
"name": "Main",
"userCode": "1234"
}
]
}
]After auto-discovery (what config.json looks like once the panel has connected)
The plugin appended a zones block. You can adjust each zone's type here (or in the Homebridge UI); the plugin will not overwrite your changes.
"platforms": [
{
"platform": "PimaForce",
"name": "Pima FORCE",
"port": 7780,
"account": 1234,
"partitions": [
{
"id": 1,
"name": "Main",
"userCode": "1234"
}
],
"zones": [
{ "zone": 1, "name": "Front Door", "type": "contact" },
{ "zone": 2, "name": "Living Room PIR", "type": "motion" },
{ "zone": 3, "name": "Kitchen Smoke", "type": "smoke" },
{ "zone": 4, "name": "Bathroom Leak", "type": "leak" }
]
}
]Advanced config (all features)
Multiple partitions with per-partition armModes, an explicit siren block, a credential-only partition, and a bypassable smoke zone. Zones are still auto-discovered — you customize type and any bypass after the fact.
"platforms": [
{
"platform": "PimaForce",
"name": "Pima FORCE",
"port": 7780,
"account": 1234,
"encoding": "windows-1255",
"debug": false,
"siren": {
"enabled": true,
"name": "Alarm Siren"
},
"partitions": [
{
"id": 1,
"name": "Main",
"userCode": "1234",
"armModes": { "away": true, "stay": true, "night": false }
},
{
"id": 2,
"name": "Garage",
"userCode": "5678",
"armModes": { "away": true, "stay": false, "night": false }
},
{
"id": 3,
"name": "Smoke Partition",
"userCode": "9012",
"exposeAccessory": false
}
],
"zones": [
{ "zone": 1, "name": "Front Door", "type": "contact" },
{
"zone": 3,
"name": "Kitchen Smoke",
"type": "smoke",
"partition": 3,
"bypass": { "enabled": true, "autoClearMinutes": 30 }
}
]
}
]Partition 3 above is configured but not shown in HomeKit — see partition.exposeAccessory. Zone 3 gets a Kitchen Smoke Bypass switch that clears itself after 30 minutes; see "Zone bypass" below for why a smoke zone needs one.
Configuration Parameters
Platform-wide settings
| Parameter | Description | Required | Default | Type |
|-------------|--------------------------------------------------------------------------------------------------------------------------|----------|------------------|---------|
| name | How the plugin appears in Homebridge logs. | No | Pima FORCE | String |
| port | TCP port the panel dials in to. Must match the CMS path port on the panel. | Yes | 7780 | Integer |
| account | Account ID configured on the panel's CMS path. | Yes | 1234 | Integer |
| encoding | Character encoding for zone/user names returned by the panel. Set to utf-8 for English-only installs; any encoding TextDecoder accepts is valid (windows-1255, iso-8859-1, etc.). If names appear as ? in HomeKit the encoding is wrong. | No | windows-1255 | String |
| debug | When on, every JSON frame received from / sent to the panel is logged at info level (passwords are redacted). Noisy. | No | false | Boolean |
| siren | External-siren accessory config — see "Siren settings" below. | No | enabled | Object |
| partitions| One entry per panel partition you want to expose. | Yes | — | Array |
| zones | Zones exposed as HomeKit sensors. Auto-populated by the plugin on first panel connect; appended to as new zones appear on the panel. You may edit each entry's type (and name, if you want to override the panel's name). Never delete entries unless the panel slot is genuinely gone. | No | auto-populated | Array |
Siren settings
| Parameter | Description | Required | Default | Type |
|-------------------|-------------------------------------------------------------------------------------------------------------------|----------|----------------|---------|
| siren.enabled | Off to suppress the siren accessory entirely. | No | true | Boolean |
| siren.name | Display name in HomeKit. | No | Alarm Siren | String |
Partition settings
| Parameter | Description | Required | Default | Type |
|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------|----------|------------------------|---------|
| partition.id | Partition number on the panel (1–16). | Yes | — | Integer |
| partition.name | Display name in HomeKit. | Yes | — | String |
| partition.userCode | User code for arming / disarming this partition. Stored in plain text in config.json — protect access to the host accordingly. | Yes | — | String |
| partition.armModes | Per-partition checkboxes for which HomeKit armed modes to expose. DISARM is always available — see "Arm-mode mapping" below. | No | all enabled | Object |
| partition.exposeAccessory | Set false to keep the partition as a credential only, with no HomeKit security-system tile. Useful for a partition that exists solely to authorise operations on its zones — see "Zone bypass" below. | No | true | Boolean |
Arm-mode mapping
HomeKit's Security System has three armed target states; each maps to a specific PIMA arm operation:
| HomeKit state | PIMA mode | optype |
|---------------|----------------|--------|
| AWAY_ARM | Full Arm | 12 |
| STAY_ARM | Home 1 Arm | 13 |
| NIGHT_ARM | Home 2 Arm | 14 |
| DISARM | Disarm | 17 |
Per-partition armModes toggles correspond to those three armed states (away, stay, night — booleans). Disabling one removes it from the picker in the Home app for that partition. DISARM is always available.
Zone settings
| Parameter | Description | Required | Default | Type |
|-----------------|--------------------------------------------------------------------------------------------------------------------------|----------|-------------|---------|
| zone.zone | Zone number on the panel. | Yes | — | Integer |
| zone.name | Display name in HomeKit. | Yes | — | String |
| zone.type | HomeKit sensor type: contact (door/window), motion, leak, smoke. Affects only the HomeKit icon and automation primitives — the panel-side semantics are identical. | No | contact | String |
| zone.partition | Partition that owns this zone. Optional and informational — see "Zone bypass" below; any configured user code can bypass any zone. | No | — | Integer |
| zone.bypass | Expose a bypass switch for this zone — see "Zone bypass" below. | No | disabled | Object |
Zone bypass
Some zones are 24-hour: they stay armed no matter what their partition is doing. Smoke and flood detectors are usually wired this way, which means disarming the partition a smoke detector sits on does not stop it alarming. You can check on your own panel by reading parameter 2149 while the partition is disarmed — a zone still reporting bit 10 (Armed) is 24-hour.
The only thing that suppresses such a zone is bypass (panel parameter 2150). The classic case is cooking something smoky without tripping the kitchen detector.
{
"zone": 13,
"name": "Kitchen Smoke",
"type": "smoke",
"partition": 3,
"bypass": { "enabled": true, "autoClearMinutes": 30 }
}This adds a separate Switch accessory (default name <zone name> Bypass). On = bypassed: the zone will not alarm.
| Parameter | Description | Default |
|------------------------------|-----------------------------------------------------------------------------------------------------------------|----------------------|
| bypass.enabled | Expose the switch. | false |
| bypass.name | Accessory name. | <zone name> Bypass |
| bypass.autoClearMinutes | Clear the bypass automatically after this long, so a forgotten bypass can't leave a detector disabled. 0 disables the timer. | 30 |
Notes:
- A bypassed smoke detector is a disabled smoke detector. The auto-clear timer exists for that reason; think carefully before setting it to
0. - The zone's sensor reports
StatusActive = falsewhile bypassed, so a suppressed detector doesn't look healthy in the Home app. - Bypasses applied at the keypad show up too — the panel reports them the same way, so HomeKit stays in sync either direction.
zone.partitionis optional. The panel filters parameter reads by user code but not writes, so any configured user code can bypass any zone — including zones whose partition that code can't otherwise see. Setting it just documents ownership and picks which code the plugin sends. (This also means a low-privilege user code is enough to disable any detector on the panel; that's the panel's design, not the plugin's.)partition.exposeAccessory: falseis for a partition you want configured but not shown — note that a partition with no accessory also has nowhere to reportALARM_TRIGGERED, so its alarms will only appear in the log and on the individual zone sensors.
Features
- Per-partition Security System accessory; tracks AWAY / STAY / NIGHT / DISARM and ALARM_TRIGGERED on burglary events.
- Per-zone HomeKit sensor of the configured type (contact / motion / leak / smoke).
- Global Switch for the external siren — toggle off to mute an active siren (turning it on from HomeKit is rejected; the plugin won't sound the siren on demand).
- Optional per-zone bypass Switch with an auto-clear timer — the only way to silence a 24-hour zone such as a smoke or flood detector.
- State sync from any source (keypad, monitoring station, mobile app) reflected in HomeKit, not only changes initiated from the plugin.
- Graceful handling of events from unconfigured partitions / zones — logged once, never crash.
- Optional
debugmode logs every JSON frame in / out of the panel (passwords redacted).
Issues & Debug
If you experience any issues with the plugin please open an issue on GitHub. Set "debug": true in the platform config and include the relevant log lines — every frame in / out of the panel is logged at info level when debug is on, with passwords redacted, which makes diagnosing protocol-level issues much faster.
When the panel rejects a request (e.g. unknown user code or insufficient authority), the plugin logs a panel NAK line at warn level with the panel's reason string — useful when arm / disarm or siren-mute commands appear to do nothing.
Credits
100% of the code in this repository — driver, plugin, protocol layer, tests, CI, and this README — was written by Claude Code (Anthropic's AI coding assistant) under direction from @electricmonk. Maintainer's contributions were the project goals, panel access for protocol reverse-engineering, real-world testing of every feature against an actual Pima FORCE installation, design review, and bug reports from production use. Mention if you fork or extend.
License
This plugin is released under the GNU Lesser General Public License v3.0 or later. See LICENSE for the full text.
Support homebridge-pima-force
Plugin development and maintenance takes time. If this plugin saved you a few hours of poking at panel manuals and packet captures and you'd like to say thanks, donations are welcome: