homebridge-prometheus-heating
v1.0.0
Published
Homebridge platform: room heating controlled via Prometheus temperature metrics and Shelly relays (hysteresis or PWM).
Downloads
183
Maintainers
Readme
homebridge-prometheus-heating
Homebridge platform that exposes one Thermostat per room, reads room temperatures from Prometheus, and controls heating via Shelly relays using hysteresis (corridor) control by default, with optional PWM.
Requirements
- Node.js >= 24
- Homebridge >= 1.8.0
- A Prometheus server exposing temperature metrics
- Shelly relay devices (Gen1 or Gen2/Gen3) for each room
Installation
npm install -g homebridge-prometheus-heatingAdd the platform in your Homebridge config (or use the Homebridge UI):
{
"platforms": [
{
"platform": "PrometheusHeatingPlatform",
"name": "Prometheus Heating",
"prometheus": {
"baseUrl": "http://prometheus:9090"
},
"rooms": [
{
"id": "living",
"displayName": "Living Room",
"promQuery": "room_temperature_celsius{room=\"living\"}",
"shelly": { "host": "192.168.1.10", "generation": "auto" }
}
]
}
]
}Configuration (camelCase)
| Field | Required | Description |
| ------------------------------------------ | -------- | -------------------------------------------------- |
| name | Yes | Platform display name |
| prometheus.baseUrl | Yes | Prometheus base URL |
| prometheus.queryTimeoutMs | No | Query timeout in ms (default 5000) |
| prometheus.auth.mode | No | none or bearer; if bearer, set bearerToken |
| control.controlMode | No | hysteresis (default) or pwm |
| control.pollIntervalMs | No | Poll interval in ms (default 30000) |
| control.hysteresisC | No | Corridor half-width in °C (default 0.5) |
| control.minOnMs / control.minOffMs | No | Min on/off time in ms (default 600000) |
| rooms | Yes | Array of room configs |
| logging.debug / logging.logPromQueries | No | Optional logging flags |
Each room must have: id, displayName, promQuery, shelly.host. Optional: shelly.generation (auto / gen1 / gen23), shelly.switchId, targetTemperatureC, minTargetTemperatureC, maxTargetTemperatureC, and override (e.g. pollIntervalMs, minOnMs, minOffMs, deadbandC).
PromQL examples
room_temperature_celsius{room="living"}last_over_time(temperature_celsius[5m])temp_sensor_celsius{job="room-sensors", room="bedroom"}
Your query should return one sample. Stale data (older than control.staleAfterMs) turns heating off.
Shelly Gen1 vs Gen2/Gen3
- Gen1:
/statusand/relay/{id}?turn=on|off. Setshelly.generationtogen1if auto-detect fails. - Gen2/Gen3: JSON-RPC at
/rpc(Switch.Set,Switch.GetStatus). Usegen23to force.
Manual relay toggles are re-asserted by the plugin on the next poll.
Control behaviour
- Hysteresis (default): Heat on when temp < target − hysteresis; off when temp ≥ target + hysteresis. Min on/off times avoid short cycling.
- PWM (optional): Time-proportional output over a configurable cycle; respects min on/off.
- Safety: Stale or invalid temperature turns heating off. On startup, relay defaults to off until a valid sample is received.
- Immediate user response: When a user changes the target temperature (e.g. via HomeKit), a full control evaluation runs immediately — bypassing
minOnMsandminOffMsfor that single evaluation. Subsequent periodic ticks resume normal min-cycle enforcement. This means the relay can switch sooner than the configured minimum on/off times when the user explicitly changes the setpoint; setminOnMs/minOffMsaccordingly if relay wear is a concern.