npm package discovery and stats viewer.

Discover Tips

  • General search

    [free text search, go nuts!]

  • Package details

    pkg:[package-name]

  • User packages

    @[username]

Sponsor

Optimize Toolset

I’ve always been into building performant and accessible sites, but lately I’ve been taking it extremely seriously. So much so that I’ve been building a tool to help me optimize and monitor the sites that I build to make sure that I’m making an attempt to offer the best experience to those who visit them. If you’re into performant, accessible and SEO friendly sites, you might like it too! You can check it out at Optimize Toolset.

About

Hi, 👋, I’m Ryan Hefner  and I built this site for me, and you! The goal of this site was to provide an easy way for me to check the stats on my npm packages, both for prioritizing issues and updates, and to give me a little kick in the pants to keep up on stuff.

As I was building it, I realized that I was actually using the tool to build the tool, and figured I might as well put this out there and hopefully others will find it to be a fast and useful way to search and browse npm packages as I have.

If you’re interested in other things I’m working on, follow me on Twitter or check out the open source projects I’ve been publishing on GitHub.

I am also working on a Twitter bot for this site to tweet the most popular, newest, random packages from npm. Please follow that account now and it will start sending out packages soon–ish.

Open Software & Tools

This site wouldn’t be possible without the immense generosity and tireless efforts from the people who make contributions to the world and share their work via open source initiatives. Thank you 🙏

© 2026 – Pkg Stats / Ryan Hefner

homebridge-systemair-vr700

v0.5.6

Published

Homebridge plugin for Systemair/Villavent VR-700 (CD panel protocol) over an RS485<->WiFi adapter (e.g. Elfin EW11)

Readme

homebridge-systemair-vr700

Homebridge plugin for a Systemair/Villavent VR-700 (DCV series) residential ventilation unit, controlled via the reverse-engineered CD panel protocol – not Modbus.

It connects through an RS485↔WiFi adapter (e.g. Elfin EW11/EW11A) wired directly to the wall-panel terminals (12V / GND / Hi / Lo) of the ventilation wall box – effectively replacing a defective or missing wall controller.

Status: works reliably in day-to-day use for fan speed (4 levels) and temperature level (6 levels), each operated individually. See the safety note below before you tinker with the protocol code.

Since 0.5.0: a learn mode that records the correct control frames directly from your own unit (instead of using the bundled frames), much lower bus load via a closed control loop, automatic bus-jam detection with a recovery pause – and the deliberately removed manual frame injection.

Prerequisite: EW11 configuration

In the EW11 web interface (default IP 10.10.100.254 as shipped):

  • Serial Port Settings: Baud Rate 57600, Data Bit 8, Stop Bit 1, Parity None, Protocol: None (transparent – not "Modbus", the unit does not speak Modbus on this bus)
  • Communication Settings: Protocol TCP Server, Local Port 502, Route Uart
  • Connect WiFi in STA mode to your home network
  • A static IP is strongly recommended (DHCP reservation in the router) – a wandering IP is the most common cause of "the plugin no longer connects"

Installation

Via npm:

npm install -g homebridge-systemair-vr700

Or locally from source, e.g. on a Raspberry Pi setup with the official Homebridge image (hb-service):

git clone https://github.com/nimacodes/homebridge-systemair-vr700.git
sudo cp -r homebridge-systemair-vr700 /var/lib/homebridge/node_modules/homebridge-systemair-vr700
sudo chown -R homebridge:homebridge /var/lib/homebridge/node_modules/homebridge-systemair-vr700
sudo systemctl restart homebridge

Note for hb-service installations: do not install via npm install <local-path> from a directory like /home/<user>/... or /tmp/... – that often only creates a symlink. If the symlink points to /tmp/..., the plugin disappears on the next reboot (Linux clears /tmp on every reboot). Copy the folder directly and completely into /var/lib/homebridge/node_modules/ as shown above instead.

Configuration

In the Homebridge config.json (or via Config UI X, config.schema.json is included):

{
  "platforms": [
    {
      "platform": "SystemairVR700",
      "name": "Ventilation",
      "ip": "192.168.0.125",
      "port": 502
    }
  ]
}

The plugin automatically creates two accessories:

  • "<Name> Speed" – fan accessory, speed in 4 levels (off/low/normal/high, 0/33/66/100 %)
  • "<Name> Temperature" – lightbulb accessory (brightness slider), maps the 6-level temperature setting (0–100 % in 20 % steps)

A lightbulb was chosen for the temperature level because HomeKit has no generic 6-step control without a unit, and a slider in the Home app UI is the closest match to the physical dial.

Optionally, learn mode can be enabled with "learn": true – strongly recommended if setting values isn't reliable for you (see below).

How it works (in brief)

The panel protocol uses 280-byte frames with header 55 AA and a CRC-8 checksum (polynomial 0x8D, no init, no reflection). The controller periodically sends state broadcasts (frame type 0x0a); a panel command (frame type 0x01) is sent right after a 0x02 frame from the controller (the panel's "send slot"). The plugin reads the broadcasts for status display and, when setting a value, sends a valid, exactly recorded command frame for the target level – preferring one recorded from your own unit via learn mode, otherwise the bundled template (lib/protocol.js).

Closed loop instead of blind repeating (bus load!): a command is only sent in the slot after a 0x02 and is stopped immediately as soon as the next broadcast confirms the target value. In the normal case a single write suffices instead of the former six. Several hard brakes also apply (lib/connection.js):

  • Minimum interval between two writes (500 ms),
  • Repeat cap per command (max. 3 attempts),
  • Per-minute budget as an absolute ceiling (max. 40 writes/minute, no matter what else happens – a safety net against any conceivable bug),
  • Bus-jam detection (see below).

After sending, the plugin additionally checks after 5 seconds whether the reported value matches the target. If it doesn't, it simply resends the exact frame once more (no reconnect, no disconnect – the closed-loop send already retried within its window, so there is nothing a reconnect would fix) and then stops quietly; the unit's next state broadcast keeps HomeKit in sync. A generation counter per control prevents fast slider dragging in the Home app from producing conflicting, mutually overtaking checks.

Bus-jam detection (against the "freeze")

It has been observed that the unit sometimes blocks communication – only garbage arrives, and only a power-cycle of the EW11 helps. Two automatics in the watchdog counter this:

  • Link dead (no bytes at all for 15 s): forced reconnect with an exponentially growing pause (capped at 60 s), so that repeated connecting/disconnecting doesn't itself become bus load.
  • Bus jam (bytes do arrive, but not a single valid frame for ~12 s): typical for collisions/garbage on the half-duplex bus. The plugin then stops all sending for ~30 s (quiet mode) and reconnects once so the bus can settle – instead of writing against it. This is the software equivalent of "briefly taking your hands off the bus". If it doesn't help long-term, only the physical EW11 power-cycle remains.

Debug mode

For targeted debugging (e.g. "why is nothing coming through right now") you can set "debug": true in the config. The plugin then logs every received and sent byte in plain hex, plus a statistic after each data chunk noting when no valid frames were found in it - this cleanly distinguishes two very different failure modes:

  • No bytes arrive at all → electrical/cabling problem, WiFi problem, or the EW11 itself isn't responding.
  • Bytes arrive, but 0 valid frames → garbage/collisions on the bus, or an unknown frame type our parser doesn't (yet) recognize.
{
  "platform": "SystemairVR700",
  "ip": "192.168.0.125",
  "debug": true
}

Important: debug mode produces a lot of log lines - set it back to false (or remove the field) after debugging.

Learn mode (recommended)

For context: the bundled command frames are real frames recorded via reverse engineering – the closest thing to the actual panel communication there is, and the trusted default basis of this plugin. They remain the default; learn mode is optional and changes nothing unless you run it.

Still, such a frame is a complete 280-byte snapshot of which only a few bytes are decoded. Because of this, setting a value can occasionally fail to take immediately – e.g. because a frame always carries both values (fan and temperature) and two quickly successive commands overwrite each other, or because embedded counter/timestamp bytes in the snapshot are stale. Learn mode helps here by recording fresh frames directly from your running unit – useful to refresh the templates, fill in missing levels, or measure a different/new device. It's not a "replacement for wrong" frames, but a way to keep the set current from the same real source.

How it works: with "learn": true the plugin enters a purely passive capture mode. It sends nothing to the unit (so it's completely harmless to the bus) and only listens: you step through all levels on the original wall panel, one by one, and the plugin maps each stable state to the corresponding real panel command frame and stores it as an exact, unmodified template.

{
  "platform": "SystemairVR700",
  "ip": "192.168.0.125",
  "learn": true
}

Procedure:

  1. Set "learn": true, restart Homebridge. A learn banner appears in the log.
  2. Step through, one by one, on the original wall panel:
    • Fan: off → low → normal → high
    • Temperature: all 6 levels
    • stay on each level for ~5 seconds.
  3. After each captured level the log shows progress (fan 3/4, temperature 5/6) and which levels are still missing. Once all are captured it says so explicitly.
  4. Set "learn": false (or remove the field), restart Homebridge. From now on the plugin prefers the learned frames of your unit; for levels not yet learned it falls back to the bundled templates.

The learned frames are stored per unit (by IP) persistently in the Homebridge storage (systemair-vr700-learned-<ip>.json) and survive restarts and plugin updates.

Requirement: learning needs an original wall panel that stays connected in parallel on the bus – only that produces the command frames (type 0x01) to learn from. If the EW11 replaces a missing panel, there is no such source; the plugin then says so clearly in the log and keeps using the default frames.

Standalone learning wizard (interactive)

If you'd rather learn the frames outside Homebridge – with a live, guided prompt instead of reading the log – there's a small command-line wizard. It connects to the EW11, listens only (never sends anything), shows a live checklist while you operate the panel, and writes the same learned-frames file the plugin reads.

Run it from the plugin directory:

node tools/learn.js --ip 192.168.0.125
# or, if the plugin is installed globally, the bundled command:
homebridge-systemair-vr700-learn --ip 192.168.0.125

Options: --port (default 502) and --out <dir> (where to write the file, default the current directory).

It shows a live status line and ticks off each level as it captures it:

  [fan=normal temp=3]  panel cmds: 42  valid frames: 118  learned: fan 2/4, temp 1/6
  ✓ captured fan level 2 ...

When finished (all levels captured, or press Ctrl‑C – progress is saved as you go) it prints the path to systemair-vr700-learned-<ip>.json. Copy that file into your Homebridge storage directory (the folder with config.json), make sure "learn" is false/absent, and restart Homebridge. Same requirement as above: the original wall panel must be connected in parallel on the bus.

Safety note (important!)

Only exact, unmodified command frames are ever sent – either the bundled templates or the ones recorded via learn mode. A dynamically assembled frame is never produced.

Earlier versions contained a function commandForState(fanLevel, tempLevel) that assembled a frame from a temperature template with overwritten fan bytes (a "Frankenstein" frame). Using it brought the real unit's controller to a freeze/reset – a power-cycle was required. That function and the earlier manual frame injection (manualFrames) were removed entirely so the footgun isn't even reachable.

If you extend the protocol: send only frames that are either unchanged from a real capture (see learn mode) or whose effect on all 280 bytes is fully understood – not just the few bytes you currently care about. Never change individual bytes of a frame while all 280 are not understood.

Alternative: Modbus

The VR-700 DCV can also speak Modbus RTU (RS-485) on a separate connector – which most other integrations build on (e.g. BeamCtrl/Airiana, various Home Assistant projects). That is considerably more robust than replaying panel frames, but requires the Modbus terminals, not the wall-panel terminals. This plugin deliberately takes the panel-protocol route (it sits on the panel bus and replaces/supplements the wall panel). If you can reach the Modbus terminals and want full sensors/control, a Modbus solution may serve you better.

Known limitations

  • No true dynamic writing of arbitrary field combinations (see above) – only the four fan levels and six temperature levels as exactly recorded target values (bundled or learned).
  • If you set fan speed and temperature in quick succession, the respective other value can briefly jump back to its last recorded state until the verify/resend reconciles it (a few seconds' delay, no data loss). Learn mode reduces this, because both values then come from the same real recorded panel reality.
  • The EW11 responded to enabled TCP keepalive probes with periodic ECONNRESET in testing – the plugin therefore deliberately uses no TCP keepalive, but its own data-based watchdog (reconnect when no broadcasts arrive for 15 seconds, with an exponentially growing pause on repeated failed reconnects, capped at 60 s - prevents repeated connecting/disconnecting from becoming bus load itself).
  • Observed, not fully explained: when the ventilation unit reports a sensor fault due to overtemperature (normal behavior in itself), the display on the physical wall panel disappears once the EW11 is connected to the bus - and the EW11 itself then also seems to receive no more data. Disconnecting the EW11 again, the panel works normally. This points more to an electrical interaction (bus loading/termination of the EW11, possibly aggravated by reduced noise immunity of the controller in the fault state) than to a pure software bug - debug mode (see above) helps observe this in detail (do any bytes arrive, and if so how many valid frames).
  • Untested: behavior over very long runtimes (weeks/months), and behavior when a second physical wall controller is actively operated at the same time.

Contributing

Issues and pull requests welcome – especially on the question of which of the still-unknown frame fields are actually safety-relevant (see the safety note above). For PRs that introduce new command frames or change existing ones, please briefly describe how/where they were tested.