homebridge-vthermo
v2.3.2
Published
Virtual thermostat for Homebridge that reads Matter temperature/contact sensors and switches a Matter On/Off relay.
Downloads
1,325
Maintainers
Readme
homebridge-vthermo
A virtual heating thermostat for Homebridge (v1.8+ and v2) that uses Matter devices: it reads Matter temperature sensors (and optional door/window sensors) and switches a Matter On/Off relay or plug. The thermostat shows up in Apple Home like a normal one.
🇭🇺 Magyar leírás lent: Magyarul
Features
- Multiple thermostats in one platform
- One or more temperature sources per thermostat, combined as average, minimum or maximum
- If a source does not answer, the others are used; the last good reading is kept for 10 minutes
- Heating pauses while any selected door/window sensor is open
- Hysteresis band and a configurable check interval
- Several thermostats can share one relay (e.g. one boiler): it stays on while any of them needs heat
- Optional relay retry after a cut-out (relay switched itself off while heat was still needed)
- Built-in Matter controller: pair Matter devices or bridges (e.g. Aqara Hub M2) from the settings page
- Settings page in English or Hungarian
- Fail-safe: if no temperature can be read, heating is switched off and the thermostat shows a fault in Apple Home
- Boiler protection: minimum relay on-time and off-time
- Frost protection: heats below a set temperature even when the thermostat is off or a window is open
- Per-sensor calibration offset, optional humidity shown on the thermostat
- Live status on the settings page (temperatures, relay, window, errors) while the plugin runs
- Devices that were paired again are reconnected to your thermostats automatically
- Pair and remove Matter devices while the plugin is running
- Optional instant updates for window sensors and relays (Matter subscriptions, experimental)
- Optional Eve app history graphs
- Battery Thread sensors (sleepy / ICD devices such as IKEA MYGGBETT) via a permanent Matter subscription instead of polling
Install
From the Homebridge UI search for homebridge-vthermo, or from a local package:
npm install -g ./homebridge-vthermo-2.0.0.tgzRunning the plugin as a child bridge is recommended.
Setup
- Open the Vthermo plugin settings in the Homebridge UI.
- Pair your Matter device or bridge: pick it from Discovered Matter nodes or use Pair by Matter code (Apple Home → device → Turn On Pairing Mode gives you a code for an extra controller).
- Add a thermostat, then pick its temperature sources, the relay and optional window sensors.
- Save and restart the Vthermo child bridge.
Pairing while the plugin is running: the settings page talks to the running plugin through a local-only (127.0.0.1), token-protected connection, so you can pair and remove devices without stopping anything. When the plugin is not running, the settings page uses the Matter controller itself.
Troubleshooting
“… is not reachable” / Resume failed … Operation timed out: Homebridge cannot reach the
Matter device at its stored address. Usually the device got a new IP address or it is on a
different subnet/VLAN than Homebridge (mDNS discovery does not cross subnets). Check from the
Homebridge host:
ping <device-ip>avahi-browse -rt _matter._tcpFix it with a DHCP reservation for the device. If it lives in another subnet on purpose, enable
an mDNS reflector on your router and allow routing, or set a fixed address for the node in the
settings page (nodeAddressOverrides).
“… no longer accepts this controller (NoSharedTrustRoots)”: the device lost its Matter pairing (e.g. after a reset or when the controller was removed in the Aqara/Apple Home app). Remove the pairing in the settings and pair the device again; your thermostat selections are reconnected automatically.
Battery Thread sensors (sleepy / ICD devices), e.g. IKEA MYGGBETT: they sleep between reports,
so Vthermo never polls them; it keeps a Matter subscription and uses the values it delivers. A value
older than 15 minutes counts as closed (window) and raises a fault. To pair one that is already in
Apple Home: Home app → device → Turn On Pairing Mode, then paste the code in Pair by Matter code
and keep the device awake (open/close the door) while pairing. The Homebridge host needs IPv6 and a
route to the Thread network: on Linux enable IPv6 (SLAAC) on the interface and accept the border
routers' route information (net.ipv6.conf.<if>.accept_ra_rt_info_max_plen=64, made persistent).
Vthermo logs a warning at startup when either is missing.
Several network interfaces (Docker, LXC): set matterInterface (e.g. br0) so Matter discovery
only uses the interface that reaches your devices.
Detailed logging: turn on Detailed logging in the settings. For deep Matter protocol traces
start Homebridge with MATTER_LOG_LEVEL=debug.
Configuration
The settings page writes the config for you. Reference:
| Option | Default | Description |
| --- | --- | --- |
| language | auto | Settings page language: auto, en, hu |
| enableVerboseLogging | false | Detailed runtime logs |
| instantUpdates | false | Experimental: Matter subscriptions for window sensors and relays |
| enableHistory | false | Eve app history (stored under vthermo-history/) |
| matterInterface | | Limit Matter discovery to one interface, e.g. br0 |
| nodeAddressOverrides | [] | [{ "nodeId": "...", "address": "192.168.1.68:5540" }] fixed addresses for nodes mDNS cannot find |
| thermostats[].name | | Name in Apple Home |
| thermostats[].temperatureSources | | Matter temperature endpoints (selected in the UI) |
| thermostats[].temperatureAggregation | average | average, minimum, maximum |
| thermostats[].switchTarget | | Matter On/Off endpoint (relay, plug) |
| thermostats[].contactSensors | [] | Matter contact sensors that pause heating while open |
| thermostats[].hysteresis | 0.5 | Total band in °C (0.1–5) |
| thermostats[].checkIntervalSeconds | 30 | Control cycle interval (5–3600 s) |
| thermostats[].relayRetryEnabled | false | Switch the relay on again after a cut-out |
| thermostats[].relayRetryDelayMinutes | 5 | Wait time before the retry (1–180 min) |
| thermostats[].defaultTargetTemperature | 21 | Initial target |
| thermostats[].minTargetTemperature / maxTargetTemperature | 10 / 30 | Allowed target range (5–35 °C) |
| thermostats[].minOnMinutes / minOffMinutes | 0 / 0 | Boiler protection: minimum relay on/off time (0–60 min) |
| thermostats[].frostProtectionTemperature | 0 | Heat below this even when off or a window is open (0 = disabled, 3–15 °C) |
| thermostats[].humiditySource | | Optional Matter humidity endpoint shown on the thermostat |
| temperatureSources[].offset | | Per-sensor calibration in °C (−10…10), set on the settings page |
Matter controller state is stored in the Homebridge storage folder under vthermo-matter/.
Support
If Vthermo keeps your home warm, you can buy me a coffee ☕. Thank you!
Development
npm install
npm test
npm packEnd-to-end tests against a virtual Matter device (see test/e2e/):
MATTER_MDNS_NETWORKINTERFACE=en0 node test/e2e/virtual-device.mjs &
MATTER_MDNS_NETWORKINTERFACE=en0 node test/e2e/run.mjsFor the sleepy-device scenario start the device with VTHERMO_TEST_ICD=1 and run test/e2e/run-icd.mjs.
Magyarul
Virtuális fűtési termosztát Homebridge-hez (v1.8+ és v2), ami Matter eszközökkel dolgozik: Matter hőmérséklet-érzékelőket (és opcionálisan ajtó/ablak érzékelőket) olvas, és egy Matter On/Off relét vagy konnektort kapcsol. Az Apple Home-ban normál termosztátként jelenik meg.
Tudja
- Több termosztát egy platformon
- Termosztátonként több hőmérséklet-forrás (átlag, minimum vagy maximum)
- Ha egy forrás nem válaszol, a többit használja; az utolsó jó értéket 10 percig megtartja
- Nyitott ajtó/ablak esetén a fűtés szünetel
- Hiszterézis és állítható ellenőrzési időköz
- Több termosztát használhatja ugyanazt a relét (pl. egy kazán): addig marad bekapcsolva, amíg bármelyiknek fűtés kell
- Opcionális relé újrakapcsolás, ha a relé magától kikapcsol (pl. kazánvédelem)
- Beépített Matter vezérlő: Matter eszközök vagy bridge-ek (pl. Aqara Hub M2) párosítása a beállítások oldalon
- Magyar vagy angol beállítások oldal
- Biztonság: ha egyik hőmérséklet sem olvasható, kikapcsolja a fűtést és hibát jelez az Apple Home-ban
- Kazánvédelem: minimális bekapcsolt és kikapcsolt relé idő
- Fagyvédelem: kikapcsolt termosztát vagy nyitott ablak mellett is fűt egy beállított hőmérséklet alatt
- Érzékelőnkénti korrekció, opcionális páratartalom a termosztáton
- Élő állapot a beállítások oldalon (hőmérsékletek, relé, ablak, hibák), miközben a plugin fut
- Az újrapárosított eszközök automatikusan visszakerülnek a termosztátokhoz
- Párosítás és törlés a plugin leállítása nélkül
- Opcionális azonnali frissítés ablakérzékelőkre és relékre (Matter feliratkozás, kísérleti)
- Opcionális Eve app előzménygrafikonok
- Elemes Thread érzékelők (alvó / ICD eszközök, pl. IKEA MYGGBETT) állandó Matter feliratkozással, lekérdezés nélkül
Beállítás
- Nyisd meg a Vthermo plugin beállításait a Homebridge UI-ban.
- Párosítsd a Matter eszközt vagy bridge-et: válaszd ki a Talált Matter eszközök közül, vagy használd a Párosítás Matter kóddal részt (Apple Home → eszköz → Párosítási mód bekapcsolása ad kódot egy további vezérlőhöz).
- Adj hozzá termosztátot, és válaszd ki a hőmérséklet-forrásokat, a relét és az opcionális ablakérzékelőket.
- Mentsd el, és indítsd újra a Vthermo child bridge-et.
Párosítás futó plugin mellett: a beállítások oldal egy csak helyi (127.0.0.1), tokennel védett kapcsolaton át a futó pluginnal párosít, így semmit sem kell leállítani.
Hibaelhárítás
„… is not reachable” / Resume failed … Operation timed out: a Homebridge nem éri el a Matter
eszközt a tárolt címen. Általában új IP címet kapott, vagy más alhálózaton/VLAN-on van, mint a
Homebridge (az mDNS nem megy át alhálózatok között). Ellenőrizd a Homebridge gépről a ping és az
avahi-browse -rt _matter._tcp paranccsal. Megoldás: fix DHCP cím az eszköznek, mDNS reflektor a
routeren, vagy fix cím megadása a beállítások oldalon.
Támogatás