iobroker.danfoss-ally
v0.2.19
Published
ioBroker adapter for Danfoss Ally Cloud API (OAuth2)
Downloads
586
Readme
ioBroker.danfoss-ally

Cloud adapter for Danfoss Ally™ — using OAuth2 (Client Credentials).
Reads temperature, humidity, valve position, and battery data for all devices in your Ally account,
and allows targeted single writes without forced mode changes or chained sequences.
Features
- Direct connection to the Danfoss Ally Cloud API
- Automatic OAuth2 token refresh
- Discovers all registered devices
- Reads all available sensor and control data (temperature, humidity, battery, valve position, etc.)
- Converts raw Danfoss values (×0.1) into real units (°C, %)
- Fully automatic polling with configurable interval
- Supports single, isolated write commands from ioBroker to the cloud
Highlights
- Single Writes — each state is sent independently (no automatic mode switching)
- Smooth Sync Logic
- Anti-Race (5s): skip one poll right after a local write
- Hold Window (1min): protect recent local values from overwrite
- Lag Suppress (15s): ignore temporarily outdated cloud data
- Soft Refresh (~1.5s): re-fetch only affected states after each write
- Quiet Logging — info-level for clean operation, debug-level for diagnostics
- Auto Scaling — temperatures/humidity auto-converted to °C / %
Note: Cloud updates from the Danfoss Ally app may appear in ioBroker with a short delay (1–2min).
Supported Devices
- Danfoss Ally™ TRV (Radiator thermostats)
- Danfoss Icon2 RT (Room thermostats)
- Danfoss Icon2 Controller
- Danfoss Ally™ Boiler Relay
- Danfoss Ally™ Gateway
(other Danfoss devices auto-discovered)
Configuration
Go to Instances → danfoss-ally → Settings
| Field | Description |
| -------------------- | ------------------------------------------------------------------- |
| API Key / Secret | Your Danfoss Developer App credentials |
| Token URL | OAuth2 token endpoint (e.g. https://api.danfoss.com/oauth2/token) |
| API Base URL | e.g. https://api.danfoss.com/ally |
| Scope | Optional OAuth2 scope (e.g. read write) |
| Polling Interval | Default 300s |
Shorter intervals update faster but create more API traffic. 30–60s is a good balance.
API Key: your-client-id
API Secret: your-client-secret
Token URL: https://api.danfoss.com/oauth2/token
API Base URL: https://api.danfoss.com/ally
Polling: 300States
Each discovered device creates a device tree:
danfoss-ally.0.<device_id>.*
Status vs Control States
The adapter separates read-only status values from writeable control values.
Status channel
danfoss-ally.0.<deviceId>.status.*
These states mirror values received from the Danfoss Cloud API.
Properties:
- read: true
- write: false
Do not write to these states from scripts.
Examples:
status.temp_currentstatus.temp_setstatus.modestatus.humidity_valuestatus.battery_percentage
Control channel
danfoss-ally.0.<deviceId>.control.*
These states are intended for user interaction and can be written from scripts or Blockly.
Properties:
- read: true
- write: true
Examples:
control.temp_setcontrol.manual_mode_fastcontrol.modecontrol.child_lock
The adapter automatically sends commands to the Danfoss Cloud and updates the corresponding status values.
Reading examples
| State | Description | Unit |
| -------------------------------------- | --------------------------------------------- | ---- |
| status.temp_current | Current temperature | °C |
| status.humidity_value | Relative humidity | % |
| status.battery_percentage | Battery level | % |
| status.mode | Current mode (auto, manual, at_home, …) | – |
| status.work_state, status.output_status, status.fault | Status or error | – |
| status.upper_temp / status.lower_temp | Temperature limits | °C |
All numeric values are scaled from ×0.1 → °C/% automatically.
Writing
The adapter supports targeted writes to each controllable state without automatic mode changes.
This gives you full control in Blockly, JavaScript, or custom logic scripts.
| Writable state | Expected value / behavior |
| ----------------------------------------------------------------------------- | --------------------------------------------------------------- |
| control.temp_set | Target temperature (°C, 0.5steps; sent ×10) |
| control.manual_mode_fast | Fast manual setpoint command / fallback for Ally TRVs |
| control.at_home_setting, control.leaving_home_setting, control.pause_setting, control.holiday_setting | Preset temperatures |
| control.mode | manual, at_home, leaving_home, pause, holiday, auto |
| control.child_lock | true / false |
| control.SetpointChangeSource | Externally or schedule |
Adapter does not auto-switch modes when writing setpoints — you decide in your logic.
Example (Blockly / Script)
// Manual mode
setState("danfoss-ally.0.<id>.control.mode", "manual");
setState("danfoss-ally.0.<id>.control.temp_set", 21.5);
// At home
setState("danfoss-ally.0.<id>.control.mode", "at_home");
setState("danfoss-ally.0.<id>.control.at_home_setting", 21.0);
// Leaving home
setState("danfoss-ally.0.<id>.control.mode", "leaving_home");
setState("danfoss-ally.0.<id>.control.leaving_home_setting", 19.0);
// Pause
setState("danfoss-ally.0.<id>.control.mode", "pause");
setState("danfoss-ally.0.<id>.control.pause_setting", 5.0);
// Holiday
setState("danfoss-ally.0.<id>.control.mode", "holiday");
setState("danfoss-ally.0.<id>.control.holiday_setting", 10.0);
// Child lock
setState("danfoss-ally.0.<id>.control.child_lock", true);
// Explicit source (usually not needed)
setState("danfoss-ally.0.<id>.control.SetpointChangeSource", "Externally"); // or 'schedule'Write commands must target the
control.*states.
Thestatus.*states are read-only mirrors from the Danfoss Cloud.
Synchronization Logic
| Mechanism | Duration | Purpose | | ---------------- | -------- | --------------------------------------- | | Anti-Race | 5s | Skip one poll after local write | | Hold | 1min | Prevent cloud overwrite of local writes | | Lag Suppress | 15s | Ignore stale cloud data | | Soft Refresh | ~1.5s | Re-fetch only affected states |
These mechanisms ensure smooth synchronization between ioBroker and the Danfoss Cloud without flickering or value loops.
Logging
The adapter provides detailed debug-level information for diagnostics but remains quiet during normal operation.
ack=trueupdates appear only in debugHOLD,MATCH,SUPPRESS→ debug-level, harmless diagnostics- API errors (
HTTP 400/401) retried automatically (logged at debug) - Clean info-level summary after every poll:
Poll Summary Example
✅ Updated 13 devices. Changed=2, Skipped=253, Held=1
📡 Found devices, updating states...
⏸️ Skipping poll (anti-race 5000ms)Example Log Output
🔄 Starting Danfoss Ally adapter...
🔑 Refreshing OAuth2 token...
✅ Token acquired. Expires in ~3599 s
📡 Found 13 devices, updating states...
✅ Updated 13 devices from Danfoss Ally Cloud.
⏱ Polling interval set to 300 sToken Handling
- Uses OAuth2 Client Credentials Flow
- Token auto-request on startup, refresh before expiry
- On
401 Unauthorized: refresh + retry once - Tokens kept in memory, never stored
- Optional
scope/audiencesupported - All token events visible in debug log
API Endpoints
The adapter communicates with the Danfoss Ally Cloud API (base URL configurable).
| Method | Endpoint | Purpose |
| ------ | ------------------------ | --------------------------- |
| POST | /oauth2/token | Request access token |
| GET | /devices | Discover devices |
| GET | /devices/{id}/status | Read device telemetry |
| GET | /devices/{id} | Fallback for missing status |
| POST | /devices/{id}/commands | Send single write command |
Headers:Authorization: Bearer <token>Content-Type: application/json
Optional: X-App-Key, X-Tenant-Id, etc.
Error Handling:
- 400: invalid header/value → logged
- 401: token refresh + retry
- 5xx: retried next poll
- Temperature writes auto-scaled ×10 (e.g. 21.5 → 215)
Polling
- Default: 300s (configurable)
- Updates only changed values
- Includes all anti-race / hold / lag / soft-refresh logic above
- Info summary after each poll shows changed, skipped, and held states
Writes
temp_setfirst tries a combinedSetpointChangeSource+temp_setcommand- Ally TRVs also get
manual_mode_fastwhen the datapoint exists, because some devices report the manual setpoint there - Polling updates
status.*only;control.*remains a pure write channel to avoid feedback loops - Mode + temperature must be written separately
- Values are clamped to allowed limits, scaled ×10
child_lock: tries0/1, retriestrue/falseon 400 errorSetpointChangeSource: optional;temp_setattempts"Externally"for Ally TRVs- If the cloud later reports the old setpoint again, the adapter logs a warning instead of silently accepting it
All send, retry, and confirm logs appear at debug level.
Changelog
0.2.19
- Stopped polling from writing cloud values back into
control.*states to avoid feedback loops with Loxone/scripts - Added
state.fromto debug write logs so external write sources can be identified - Added direct status fallback for devices that are listed without status values, improving Boiler Relay datapoints
- Reduced poll debug noise: the initial run still logs all
SETlines, later polls summarize changed values per device
0.2.18
- Improved Ally TRV setpoint writes by additionally sending
manual_mode_fastwhen available - Added explicit warnings when the Danfoss Cloud does not confirm the requested setpoint
- Improved device naming/detection for relay-like devices so the Boiler Relay is easier to identify
0.2.17
- Improved Ally TRV
temp_setwrites by tryingSetpointChangeSource=Externallyandtemp_setas one combined command first - Falls back to
temp_setonly if Danfoss rejects the combined command - Fixed
control.switchsubscriptions for Icon2 / Boiler Relay writes - Added alias handling for
Occupied_Setpoint - Fixed jsonConfig header validation warning
0.2.16
- Fixed
temp_setfor Ally TRVs (SetpointChangeSource=Externallyauto-sent) - Fixed wrong path for
lower_temp/upper_tempclamp - Fixed
OccupiedSetpointscaling (÷100 instead of ÷10) - Added type hints for 16 new data points (
MeasuredValue,pi_heating_demand,window_state, etc.) Icon2 switchstate is now writable- Fixed jsonConfig admin validation warning (missing
sizeproperty) - Added Boiler Relay to supported devices
Development
npm i
node main.jsor install via ioBroker development tooling.
License
MIT License
Copyright (c) 2025-2026 Author [email protected]
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.