iobroker.mspa
v0.3.4
Published
ioBroker adapter for MSpa Hot Tub cloud control
Downloads
3,525
Readme
ioBroker.mspa
Tests:
MSpa Adapter for ioBroker
Controls MSpa hot tubs via the MSpa Cloud API.
Supports heating, filter, UVC, bubble and jet control with full automation via time windows, PV surplus and frost protection.
Features
Device Control
- 🌡️ Read/set water temperature & target temperature (20–42 °C, 0.5 °C steps) – values outside this range are rejected with a log warning
- 🔘 Turn heater, filter, bubble, jet, ozone and UVC on/off
- 🔗 Auto-dependency management:
- Switching heater ON → automatically starts the filter pump first (device requirement)
- Switching UVC ON → automatically starts the filter pump first (device requirement)
- Switching filter OFF → automatically stops heater, UVC and bubble first (API requirement)
- 📊 Automatic heating & cooling rate calculation (°C/h, moving EMA average)
→ requiresheat_state = 2 or 3orheater = on, and a minimum 3-minute measurement window - ⏱️ ETA as
hh:mmuntil target temperature is reached (status.heat_target_temp_reached)
→ calculated fromcomputed.heat_rate_per_hourand the target/water temperature delta; capped at 48 h,00:00when not heating - ⚡ Power failure detection with optional state restoration
- 🌍 3 server regions: Europe (ROW), USA, China
- 🔒 Rate limiter (max. 2.5 requests/second)
- 🚀 Rapid polling after commands (1-second interval for 15 s) – running poll timer is cancelled immediately so ACK arrives within ~2 s
Time Window Control
- ⏰ Unlimited configurable time windows (weekday selection, start/end time, overnight ranges supported)
- 📋 Per-window control of heating (with target temperature), filter pump and UVC
- 🔗 UVC only active when filter pump is running
- 🕐 Configurable pump follow-up time after window ends (pump keeps running N minutes)
- ALL-OFF window: set
action_filter = falseANDaction_heating = false→ the adapter actively shuts down heater, UVC and filter when the window starts
→ use this to force everything off at a specific time (e.g. 22:00–06:00) - PV windows are only activated when the current time and weekday match the configured window
PV Surplus Control
- ☀️ Automatic activation when PV surplus exceeds configurable threshold (W)
- 🌥️ Configurable cloud-protection delay before deactivation (minutes)
- 📉 Hysteresis to prevent rapid on/off switching
- 📋 Independent of time window control – can be combined
computed.pv_active–trueonly when a PV-enabled time window is currently open (correct day + time) AND surplus is above threshold
→ automatically set tofalsewhen the time window ends or at night (no manual reset needed)computed.pv_deactivate_remaining– remaining minutes of the cloud-protection delay (live countdown)- Staged deactivation – when surplus drops, the system shuts down in steps:
- Heater OFF (immediately) – if firmware already reached target temperature (
heat_state=4), the API call is skipped - UVC OFF (after configurable delay) – but only when the daily UVC minimum runtime is reached; otherwise UVC keeps running until the minimum is met
- Filter OFF (after another delay) – but only if firmware is not actively heating (
heat_state 2/3)
- Heater OFF (immediately) – if firmware already reached target temperature (
- If PV surplus recovers during staged deactivation → all timers cancelled, previously turned-off devices re-activated
Season Control
- 📅 Define a season window (DD.MM – DD.MM) in the adapter settings
- Season can be toggled at runtime via
control.season_enabled(e.g. from VIS) – survives adapter restarts - Outside the season: polling continues, all automation is paused (time windows, PV)
- When
season_enabled = false: only frost protection (winter mode) is still allowed to run
Winter Mode (Frost Protection)
- ❄️ Protects the hot tub from freezing when left outdoors in winter
- Activates heater + filter automatically when water temperature falls to or below the configured frost threshold (°C)
- Deactivates again when temperature rises 3 °C above the threshold (hysteresis)
- Enabled/disabled via
control.winter_mode(e.g. from VIS) – survives adapter restarts - Frost threshold configured in the adapter settings (Admin → Time Control tab)
- Sends a Telegram notification when frost protection activates or deactivates
- Runs independently of
season_enabled– frost protection works even when the season is disabled
season_enabledvs.winter_mode– the difference:|
season_enabled|winter_mode| Result | |---|---|---| |true|false| Time windows + PV active, no frost protection | |true|true| Time windows + PV + frost protection | |false|false| Everything paused | |false|true| Only frost protection – all other automations paused |The two flags are independent –
winter_modedoes NOT disableseason_enabled.
Manual Override
- 🛑 Pauses all automations (time windows, PV surplus, frost protection) with a single switch
- Set
control.manual_override = trueto pause – the adapter will no longer send any commands to the device - Optional auto-resume: set
control.manual_override_duration(minutes) before enabling – the adapter resumes automatically after the configured time (0= indefinite) - When override is disabled, all automations are immediately re-evaluated with the latest device data
control.manual_overrideis always reset tofalseon adapter restart- Typical use case: control the device via the MSpa app temporarily without the adapter interfering
UVC Lamp Lifetime
- 🔦 Configure installation date and rated lifetime (operating hours) in adapter settings
- Real operating hours are counted – only while UVC is actually switched ON
- Accumulated hours are persisted across adapter restarts
status.uvc_hours_used– total accumulated UVC operating hours (writable – set manually to correct after data loss or lamp replacement)status.uvc_today_hours– UVC operating hours for today (resets at midnight)status.uvc_hours_remaining– remaining hours until rated lifetime is reached (updated every poll while UVC is ON)- Warns when lifetime is exhausted
Manual correction of
status.uvc_hours_used:
If the value shows0after data loss:
- Stop the adapter
- Set the correct value in ioBroker Admin (e.g.
120for 5 days × 24 h continuous run)- Start the adapter – it reads the persisted value and recalculates
uvc_hours_remainingimmediately
UVC Daily Ensure
- ⏱️ Ensures UVC runs a minimum number of hours per day (configurable)
- If the daily minimum is not yet reached, the adapter automatically starts UVC (and the filter pump) at the configured ensure time
control.uvc_ensure_skip_today– skip the daily ensure for today (e.g. when manually cleaning) → automatically resets at midnight
Filter Runtime Tracking
- ⏳
control.filter_running– accumulated filter pump operating hours (persisted across restarts) control.filter_reset– momentary trigger: resets the filter runtime counter to0(e.g. after filter cartridge replacement)
Consumption Tracking
- 📈 Daily kWh tracking via external energy meter datapoint
- Resets automatically at midnight
- Independent of season and time window control
Notifications (Telegram)
- 📨 Send notifications via Telegram on:
- ☀️ PV surplus activated / deactivated
- ⏰ Time window started / ended
- 📅 Season started / ended
- 🔦 UVC lamp expiry warning
- ❄️ Frost protection activated / deactivated
- 🛑 Manual override enabled / disabled (with duration if set)
- Supports multiple recipients (comma-separated usernames)
Changelog
0.3.4 (2026-05-05)
- (arteck) fix manual override
- (arteck) fix manual override
0.3.3 (2026-04-28)
- (arteck) fix heatrate
- (arteck) fix uvc stop
0.3.2 (2026-04-27)
- (arteck)
computed.pv_active– fixed: onlytruewhen a PV time window is currently open (day + time check); was previously activated outside configured windows - (arteck) Time window ALL-OFF:
action_filter=false+action_heating=falsenow actively shuts down heater, UVC and filter when the window starts - (arteck)
status.uvc_hours_remaining– now updated every poll while UVC is ON (previously only on UVC-OFF) - (arteck)
status.uvc_hours_used– now writable for manual correction after data loss or lamp replacement - (arteck)
status.time_windows_json– now writable; changes saved back to adapter config, schedulers restart immediately without adapter restart - (arteck)
heat_rate_per_hour/cool_rate_per_hour– fixed:heat_state=2was treated as inactive, rate was never computed; addedheater=onfallback - (arteck)
computed.pv_active– new state showing whether PV surplus control is currently active - (arteck) Startup restore: all persisted states now read via
getStateAsync()– fixes silent reset ofseason_enabled,winter_mode,uvc_ensure_skip_todayetc. on every adapter restart
0.3.1 (2026-04-26)
- (arteck) heater ON now auto-starts filter pump if not already running (device requirement)
- (arteck) UVC ON now auto-starts filter pump if not already running (device requirement)
- (arteck) target_temperature: added range validation (20–42 °C), invalid values rejected with log warning
- (arteck) target_temperature: uses
_adapterCommanded.heater+ live API data as fallback so temperature is sent directly when heater was just switched ON - (arteck) enableRapidPolling: running 60-second poll timer cancelled immediately, ACK arrives within ~2 s
0.3.0 (2026-04-26)
- (arteck) removed deprecated setStateAsync
License
MIT License
Copyright (c) 2026 Arthur Rupp [email protected]
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.