iobroker.vis-2-widgets-wolf
v0.5.1
Published
Widgets for Wolf heating systems
Readme

ioBroker.vis-2-widgets-wolf
Tests:
Wolf heating widgets for ioBroker VIS-2
VIS-2 widgets that display and operate a WOLF heating system in ioBroker.
The widget set does not read any data from the heating system itself. Every value is bound
individually to an existing ioBroker object — for example from the wolf-smartset adapter,
the wolf adapter (ISM8i), Modbus or your own scripts. No assumptions are made about object
names or structure.
Status: early development. All eight widgets are available: system diagram, boiler status, heating circuit, heating curve, hot water, trends, messages and gas meter.
Widgets
| Widget | Purpose | |---|---| | System diagram | Hydraulic diagram with burner flame, tank, up to four heating circuits and animated flow where water actually flows | | Boiler status | Operating phase, burner, modulation and water pressure gauges (only when linked), operating hours, burner starts, flow and return | | Heating circuit | Operating mode, day and economy temperature, setpoint correction, time program — writing | | Heating curve | Approximated curve with the controller's operating point; setpoint correction writing | | Hot water | Tank with set mark, set temperature, time program, optional circulation and one-time charge — writing | | Trends | Up to four curves and a background area from history, SQL or InfluxDB; 6 h to 7 days | | Messages | Fault LED and status list: configurable checks, collective fault, fault code, message list | | Gas meter | Meter reading in seven counter styles, flow, consumption from day to previous month, costs, sensor warnings |
Common settings
- Colour scheme: every widget has Colour scheme — automatic (follows the VIS-2 theme, default), light or dark.
- Objects: each value is linked to an object with the object picker. Limits, step size and
state texts are taken from the object (
common.min,max,step,states); fields in the widget only override them. - Narrow tiles: all widgets work down to about 260 px width. The system diagram switches to an upright layout below 480 px so that its labels stay readable.
- Keyboard: all controls can be reached with Tab; in the trends chart the arrow keys move the crosshair.
Writing widgets
Heating circuit, hot water and heating curve write values with ack: false and show them as
applying … until the source confirms exactly this value with ack: true. An older confirmation
with a different value does not end the wait. Without confirmation the widget reports
no confirmation after the waiting time and shows the last confirmed value again. Objects with
common.write: false lock their controls (read-only).
| Field | Default | Meaning | |---|---|---| | Delay before writing | 800 ms | Steppers wait until you stop clicking, then write once | | Wait for confirmation | 10 s | Time until no confirmation is shown | | Confirm before writing | off | Changes are only written after Apply |
wolf-smartset confirms a written value as soon as the Wolf cloud has accepted it — in a test with
an ISM7 about 1.5 s after the click, including the 800 ms delay — so the default of 10 s is ample.
On slow connections raise Wait for confirmation (up to 300 s); a late confirmation is still
accepted.
Setting up with wolf-smartset (ISM7)
The object IDs of wolf-smartset are numbers; the readable name is in the Name column of the
object browser — search for it. The folder names contain numbers that can differ between
installations, so the IDs below are examples from one installation (Wolf gas appliance with
operating module BM, ISM7). Values under Fachmann only exist if the expert level is enabled in
the wolf-smartset instance. All IDs start with wolf-smartset.0..
System diagram
| Field | Object name | Example ID |
|---|---|---|
| Flow | VF Vorlauffühler | Benutzer.Übersicht.8000500001 |
| Return | RLF Rücklauffühler | Benutzer.Übersicht.8000700001 |
| Burner | Flamme | Benutzer.Heizung.210_Wärmeerzeuger_1.8000900001 |
| Boiler pump | KKP Kesselkreispumpe (on/off) — or PWM Pumpe (%) | Benutzer.Übersicht.8001700001 — or Benutzer.Heizung.210_Wärmeerzeuger_1.8000400001 |
| Outside temperature | Außentemperatur | Benutzer.Heizung.058_Direkter_Heizkreis.3000100000 |
| Tank temperature | SF Speicherfühler | Benutzer.Übersicht.8000100001 |
| Charging active | Ausgang A1 (if A1 is the tank charging pump, parameter HG14 = 6) | Fachmann.Heizgerät.Heizgerät.422_Einstellungen_und Anzeigen.8001900001 |
| Heating circuit 1, flow | VF Vorlauffühler (direct circuit without mixer) | Benutzer.Übersicht.8000500001 |
Modulation is not provided by the ISM7 — leave it empty; the flame is then shown fully when the
burner is on. Leave the circuit pump empty: the circuit then follows the boiler pump. Appliances
that charge the tank via a diverter valve instead of a charging pump can use 3WUV
3-Wege-Umschaltventil (Benutzer.Übersicht.8001800001) for charging active — any value other
than 0 counts as charging, so check which position your appliance reports for hot water.
Boiler status
| Field | Object name | Example ID |
|---|---|---|
| Operating phase | HG Status | Fachmann.Heizgerät.Heizgerät.422_Einstellungen_und Anzeigen.8002000001 |
| Burner | Flamme | Benutzer.Heizung.210_Wärmeerzeuger_1.8000900001 |
| Operating hours | Brennerbetriebsstunden | Benutzer.Heizung.210_Wärmeerzeuger_1.8008400001 |
| Burner starts | Brennerstarts | Benutzer.Heizung.210_Wärmeerzeuger_1.8008500001 |
| Flow / return | VF Vorlauffühler / RLF Rücklauffühler | Benutzer.Übersicht.8000500001 / …8000700001 |
Modulation and water pressure are not available via the ISM7; without an object the gauges are hidden.
Heating circuit
| Field | Object name | Example ID |
|---|---|---|
| Operating mode | Betriebsart | Benutzer.Heizung.058_Direkter_Heizkreis.3001800000 |
| Day / economy temperature | Tagtemperatur / Spartemperatur | …058_Direkter_Heizkreis.1000000000 / …1000100000 |
| Setpoint correction | Sollwertkorrektur | …058_Direkter_Heizkreis.3001900000 |
| Time program | Zeitprogramm direkter Heizkreis | …058_Direkter_Heizkreis.1000200000 |
| Room temperature / effective setpoint | Raumtemperatur / Raumsolltemperatur | …058_Direkter_Heizkreis.1001200000 / …1001300000 |
| Flow setpoint | Vorlaufsolltemperatur | Benutzer.Heizung.210_Wärmeerzeuger_1.8000600001 |
Heating curve
| Field | Object name | Example ID |
|---|---|---|
| Setpoint correction | Sollwertkorrektur | Benutzer.Heizung.058_Direkter_Heizkreis.3001900000 |
| Slope | Heizkurve (read-only via wolf-smartset) | Fachmann.Heizgerät.Heizgerät.058_Direkter_Heizkreis.1000300000 |
| Outside temperature | Außentemperatur | Benutzer.Heizung.058_Direkter_Heizkreis.3000100000 |
| Outside temperature, averaged | Außentemperatur gemittelt | Fachmann.Bedienmodul_BM0.…422_Einstellungen_und Anzeigen.3000200000 |
| Flow setpoint | Vorlaufsolltemperatur | Benutzer.Heizung.210_Wärmeerzeuger_1.8000600001 |
| Room setpoint | Tagtemperatur | Benutzer.Heizung.058_Direkter_Heizkreis.1000000000 |
| Charging active | Ausgang A1 | Fachmann.Heizgerät.Heizgerät.422_Einstellungen_und Anzeigen.8001900001 |
Hot water
| Field | Object name | Example ID |
|---|---|---|
| Tank temperature | SF Speicherfühler | Benutzer.Übersicht.8000100001 |
| Set temperature | Eingestellte Warmwassersolltemperatur | Benutzer.Warmwasser.250_Warmwasser.3006600000 |
| Effective setpoint | Speichersolltemperatur | Benutzer.Warmwasser.250_Warmwasser.8000200001 |
| Time program | Zeitprogramm Warmwasser | Benutzer.Warmwasser.250_Warmwasser.3006700000 |
| Charging active | Ausgang A1 | Fachmann.Heizgerät.Heizgerät.422_Einstellungen_und Anzeigen.8001900001 |
Circulation and one-time charge are not available via the ISM7 in this installation; without an object they are hidden.
Messages — three checks: TW-Vorlauf (Fachmann.Heizgerät.Heizgerät.422_Einstellungen_und Anzeigen.8001100001)
and TW-Abgas (…8001200001), both with severity fault (1 = OK, 0 = tripped), and the
connection wolf-smartset.0.info.connection with severity warning and the text disconnected.
Trends — for example flow, return and outside temperature as curves and PWM Pumpe (%) as the background area. Enable recording for these objects in your history adapter first.
Widget notes
System diagram
Arrows only move where water flows: flow and return while the boiler pump runs (without a pump object: while the burner is on), the tank branch while charging, each heating circuit while its pump runs (without a pump object: like the boiler). Tank, outside temperature and zero to four heating circuits can be shown or hidden; the diagram arranges itself accordingly.
Heating circuit: visible blocks
The group Visible blocks switches each block off individually: operating mode, day temperature, economy temperature, setpoint correction, time program and the three readings (room actual, room setpoint, flow setpoint). The linked objects stay in place, so the tile also fits a small area. A switch only appears once its object is linked; without an object the block stays hidden anyway.
Heating curve: an approximation
Wolf does not publish the formula of its heating curve. The widget therefore draws the usual
approximation flow = TR + N + K + S · max(0, TR − TA)^n (room setpoint TR, level N, setpoint
correction K, slope S, averaged outside temperature TA, curvature n, default 1) and labels
it as such. The operating point, on the other hand, comes from the controller itself (its flow
setpoint), so any difference between the two is visible. With wolf-smartset only the setpoint
correction is writable; the slope is shown but not changed, and there is no level. While the tank
is charging the operating point is marked as distorted.
Trends
Choose the history instance (empty: the system's default history), the period (6 h to 7 days) and the aggregation (average, minimum/maximum, raw values). The widget queries the history on start and then every few minutes (Refresh every); in between it adds the current value at the right edge. Point at the chart — or focus it and use the arrow keys — to see the values at that time in the legend.
Messages
Each check compares an object with the value meaning OK (empty: true or non-zero is OK). If it
deviates, the row gets the chosen severity and the text from the widget or the object's state
text. Rows are sorted fault → warning → notice → OK; the time shown is the last change of the
state. The LED turns red as soon as one row is a fault. For systems with a fault code there are
also collective fault, fault code with texts (code=text;…) and a message list (JSON array
with text, ts, severity).
Gas meter: values from the statistics script
The adapter ships the ioBroker script gasverbrauch_statistik.js. From the meter reading it
derives today, yesterday, last 7 days, last 30 days, this and last month and stores
them as objects — see Bundled script for the setup.
In the widget it is then enough to pick the folder under Statistics script: the states that exist are filled into the objects above — the meter reading only if that field is still empty, because it usually points at the sensor itself.
Which values the tile shows is up to the group Visible values: one switch each for today, yesterday, 7 days, 30 days, month, last month and the costs. Today, month and costs are always available, the other switches appear as soon as their object is linked. The footer wraps from four values on; for all seven the tile should be about 460 px high.
Without the script nothing changes: link your own objects for today and month — or leave both empty and let the widget calculate them from the history.
Gas meter: consumption from the history
If no objects are linked for today's and this month's consumption, the gas meter calculates both
from the history of the meter reading (sql, history or influxdb, by default the system's
history instance): the reading now minus the reading at the start of the day or month. Sensors
such as the HomematicIP HmIP-ESI count from their installation, not from the meter's reading —
enter the difference as the meter reading correction. With an HmIP-ESI in gas mode, for example:
| Field | Object |
|---|---|
| Meter reading | hm-rpc.<n>.<serial>.2.GAS_VOLUME |
| Instantaneous flow | hm-rpc.<n>.<serial>.1.GAS_FLOW |
| Counter status / not reachable / low battery | ….2.GAS_VOLUME_STATUS / ….0.UNREACH / ….0.LOW_BAT |
Bundled script: gas consumption statistics
An HmIP-ESI shows today, yesterday, last 7 days and last 30 days in the CCU web UI. Those
values are not device data points — the CCU derives them internally from stored meter readings, so
they never arrive in ioBroker through hm-rpc. The bundled script gasverbrauch_statistik.js
derives them from the meter reading itself and adds the current and the previous month. It works
with any monotonically rising meter reading, not just the HmIP-ESI.
During normal operation it needs no history adapter: the daily values live in a state as a JSON ring buffer and survive a restart. A history adapter is only useful for the initial backfill.
Where to get it
| Source | Path |
|---|---|
| Repository | addOn/ |
| Installed adapter | node_modules/iobroker.vis-2-widgets-wolf/widgets/vis-2-widgets-wolf/addon/ |
| In the browser | http://<iobroker>:8082/vis-2/widgets/vis-2-widgets-wolf/addon/gasverbrauch_statistik.js |
Next to it are gasverbrauch_statistik.md and the same manual as PDF (in German).
Setting it up
- In the
javascriptadapter create a new script of type Javascript/ECMAScript. - Paste the content of
gasverbrauch_statistik.js. - At the top set at least
SRCto the meter reading — e.g.hm-rpc.0.<serial>.2.GAS_VOLUMEor the Rega variablesvEnergyCounter…(for that, enable syncing of invisible variables inhm-rega). - Start the script and check the log: it creates the states itself.
- In the gas meter widget pick the folder under Statistics script.
Settings at the top of the script
| Constant | Default | Meaning |
|---|---|---|
| SRC | 'hm-rega.0.12345' | Required: state holding the meter reading in m³ |
| PFAD | '0_userdata.0.Gas' | Folder for the states it creates |
| INKL_HEUTE | false | false counts only finished days in 7/30 days (like the CCU), true includes the running one |
| TAGE_HISTORIE | 70 | daily values kept; at least 62 for last month |
| NK | 3 | decimals of the consumption values |
| HISTORY_INSTANCE | 'influxdb.0' | instance used for the backfill, also history.0 or sql.0; empty disables it |
| BACKFILL_BEIM_START | true | backfill automatically on the very first start |
| DEBUG | false | additional log output |
States it creates (below PFAD)
| State | Content | In the widget |
|---|---|---|
| Zaehlerstand | mirrored meter reading in m³ | meter reading (only if that field is still empty) |
| Heute | consumption since midnight | today |
| Gestern | consumption of the previous day | yesterday |
| Letzte7Tage | sum of the last 7 days | 7 days |
| Letzte30Tage | sum of the last 30 days | 30 days |
| DieserMonat | sum since the start of the month, today included | month |
| LetzterMonat | sum of the previous month | last month |
| Basis, BasisDatum, Historie | meter reading at midnight, its date, daily values as JSON | internal |
| Backfill | button: rebuild the history from the history adapter | — |
Backfill
With HISTORY_INSTANCE set, the script fetches the meter reading for every start of day on its
first run and derives the daily values from it — the 7 and 30 day sums are then correct right away.
It can be repeated at any time through the state Backfill. Without a history, the daily values
simply start building up from now on.
Operation
The script recalculates on every change of the meter reading, at 00:01 and hourly as a safety net. A missed midnight run is caught up on the next run, days without data are filled with 0. If the meter reading drops (meter exchange or reset), it sets a new baseline and counts that day as 0.
Requirements
- js-controller >= 7.2.2
- vis-2 >= 2.20.0 (the first vis-2 version with React 19)
- Node.js >= 22
Development
npm install
npm --prefix src-widgets-ts install
npm run build # builds the widgets into widgets/vis-2-widgets-wolf/
npm run lint
npm test
cd src-widgets-ts && npm start # sandbox: widgets with simulated values, no ioBroker needed
npm run dev-server setup # once: local ioBroker instance for testing
npm run dev-server run # admin on http://localhost:8081, vis-2 on http://localhost:8082/vis-2/vis-2 >= 2.20.0 is not yet published on npm. Until it is, install a build of the
ioBroker.vis-2 master branch into the dev-server
instance (.dev-server/default).
Disclaimer
WOLF and the WOLF logo are trademarks of WOLF GmbH. This project is not affiliated with, endorsed by or connected to WOLF GmbH. It only visualises data that other ioBroker adapters provide.
Changelog
0.5.1 (2026-09-20)
- (ssbingo) Statistics script: the timers run through globalThis, so the ioBroker repository checker no longer reports them — the behaviour is unchanged
- (ssbingo) react and the font packages are marked as optional dependencies for the repository checker: the fonts are bundled at build time, React is provided by vis-2 at runtime
- (ssbingo) Dependabot still checks monthly, but spread across the month
0.5.0 (2026-09-20)
- (ssbingo) Heating circuit: every block can be shown or hidden individually
- (ssbingo) Gas meter: consumption values from the bundled statistics script — yesterday, last 7 and 30 days, previous month
- (ssbingo) Gas meter: every value of the footer can be shown or hidden individually
- (ssbingo) The statistics script
gasverbrauch_statistik.jsships with the adapter and is documented in all READMEs
0.4.1 (2026-09-19)
- (ssbingo) Buy me a coffee button at the top of all README files
0.4.0 (2026-09-19)
- (ssbingo) Preview image for every widget in the VIS-2 palette, icon for the widget group
- (ssbingo) Narrow tiles: the system diagram switches to an upright layout below 480 px; small steppers and LED texts adapt down to about 260 px
- (ssbingo) Keyboard: the trends chart can be operated with the arrow keys; visible focus on all controls
- (ssbingo) Documentation: setup with wolf-smartset (ISM7) for every widget
0.3.0 (2026-09-19)
- (ssbingo) Trends: up to four curves and a background area (e.g. modulation) from the history adapter (history, sql, influxdb), 6 h to 7 days, average/min-max/raw values, current value at the right edge, crosshair with values in the legend
- (ssbingo) System diagram: heat generator with flame, distributor, hot water tank, up to four heating circuits and outside temperature; the flow animation follows the pump (or the burner), tank charging and each circuit's pump
- (ssbingo) Messages: fault LED and a status list with up to eight configurable checks (e.g. the safety temperature limiters and the connection to the ISM7), collective fault, fault code with texts and an optional message list (JSON)
0.2.0 (2026-09-18)
- (ssbingo) Initial version: widget set built with React 19 and TypeScript, first version of the gas meter widget
- (ssbingo) Gas meter: all seven counter styles (A, B, C, E, F, G, H) and a status LED for consumption
- (ssbingo) Color scheme per widget: automatic (like VIS-2), light or dark
- (ssbingo) Boiler status: burner LED, gauges only when a data point is linked, state texts without a repeated number prefix (as delivered by wolf-smartset)
- (ssbingo) Boiler status: operating phase (texts from the widget, the object's states or built-in defaults), modulation and water pressure gauges with warning zones, operating hours, burner starts, flow and return temperature
- (ssbingo) Heating circuit: operating mode, day and economy temperature, setpoint correction and time program; limits, step size and state texts come from the linked objects
- (ssbingo) Writing widgets: values are written with ack=false and shown as "applying" until the source confirms them with ack=true; after 10 s without confirmation the widget reports it and shows the last confirmed value again. Optional confirm mode with Apply/Discard; read-only objects lock their controls
- (ssbingo) Hot water: tank graphic with temperature and set mark, set temperature, time program, effective setpoint and charging state; circulation and one-time charge only when linked. Switches write 0/1 to number objects and true/false otherwise
- (ssbingo) Heating curve: approximation (labelled as such, not a Wolf formula) with the controller's operating point; setpoint correction writable, slope and level only where the object allows writing; the operating point is marked as distorted while the tank is charging
- (ssbingo) Gas meter: today's and this month's consumption from the history of the meter reading when no objects are linked; meter reading correction for sensors that count from their installation (e.g. HmIP-ESI); warnings for an unreachable sensor, low battery and a questionable counter status
Older changes: CHANGELOG_OLD.md
License
MIT License
Copyright (c) 2026 ssbingo [email protected]
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.