signalk-victron-ble-consumer
v0.2.2
Published
Victron consumer for the official Signal K BLE Provider API
Maintainers
Readme
Signal K Victron BLE Consumer
This standalone consumer receives generic advertisement events from the gateway provider, selects configured Victron devices, and decrypts Instant Readout data exclusively on the Signal K server.
It requires Signal K Server 2.31 or newer, which provides the official BLE Provider API.
This consumer is designed for the new Signal K BLE Provider API and the
SensESP BLE Gateway transport. It receives
Victron advertisements through app.bleApi, including advertisements supplied
by remote ESP32 gateways, instead of opening a local BlueZ adapter itself. This
allows several consumers to share one BLE stream and supports coverage across
multiple vessel compartments.
Installation
Install signalk-victron-ble-consumer from the Signal K AppStore, then enable
and configure it under Server > Plugin Config. The MPPT test build is
0.2.2-mppt.0; it is a development build and is not yet an AppStore release.
To test the MPPT build directly on a Signal K server, install from the
consumer-plugin directory of a checkout. The package manifest lives there,
not at the repository root, so a branch archive URL cannot be installed
directly.
git clone -b feat/victron-mppt-support https://github.com/dirkwa/signalk-ble-gateway.git
cd ~/.signalk
npm install /path/to/signalk-ble-gateway/consumer-pluginRestart Signal K after installation, enable the plugin, and configure each device with its 32-character Victron advertisement key. The plugin requires the official Signal K BLE Provider API and a provider that supplies the advertisements.
Development installation
cd consumer-plugin
npm link
cd ~/.signalk
npm link signalk-victron-ble-consumerRestart Signal K, enable the plugin, and configure each device with a stable ID, display name, BLE MAC address, and 32-character advertisement key. The gateway provider must be enabled at the same time.
The diagnostic web application is available at:
http://SIGNALK-SERVER:3000/signalk-victron-ble-consumer/Keys are never returned by the status API or web application.
Lynx Smart BMS voltage, current, state of charge, time remaining, and
temperature are published below electrical.batteries.<id>. The web
application additionally shows consumed capacity, BMS error, I/O status, and
warning/alarm bit fields.
Orion XS is published as a charger:
electrical.chargers.<id>.voltage
electrical.chargers.<id>.current
electrical.chargers.<id>.inputVoltage
electrical.chargers.<id>.inputCurrentSmartSolar MPPT values are published as solar, the Signal K group that defines leaves for panel power and daily yield:
electrical.solar.<id>.voltage
electrical.solar.<id>.current
electrical.solar.<id>.panelPower
electrical.solar.<id>.yieldToday
electrical.solar.<id>.loadCurrentYield is published in joules, the Signal K unit for yieldToday. The
advertisement carries 0.01 kWh units, which the consumer converts.
Orion Smart DC-DC converters advertise record 0x04, which carries only
voltages:
electrical.chargers.<id>.voltage
electrical.chargers.<id>.inputVoltageFor Issue #1 testing, please compare these values with victron-ble read and
report the plugin status, Signal K paths, and any errors. Do not post the
advertisement key. If raw advertisements are needed, mask the MAC address and
share only the payload and RSSI.
Operating state and charger error are published as text alongside the measurements:
electrical.solar.<id>.chargingMode
electrical.solar.<id>.chargerState
electrical.solar.<id>.chargerError
electrical.chargers.<id>.chargingMode
electrical.chargers.<id>.chargerState
electrical.chargers.<id>.chargerErrorchargingMode is a Signal K schema leaf with an enumerated vocabulary:
bulk, acceptance, overcharge, float, equalize, unknown or other.
VE.Direct states do not map one to one, so Victron's absorption is published
as acceptance, and a state with no Signal K equivalent, such as
external_control, is published as other.
chargerState and chargerError are explicit extensions, as the schema
defines no leaf for either. They carry the exact VE.Direct names, for example
bulk, absorption, float, external_control and no_error, so the
precise device state is preserved. A code without a settled meaning is
published as unknown_<n> rather than guessed.
Shutdown reason remains diagnostic-only, visible in the web application and the status API. Unknown record types stay visible as raw data and never produce guessed measurements.
Records decoded from the specification but not yet tested
The following records are decoded from the published Victron "Extra manufacturer data" specification, with tests built from the documented layouts. No hardware was available, so their values are unverified.
0x02 battery monitor SmartShunt, BMV -> electrical.batteries.<id>
0x03 inverter Phoenix -> electrical.inverters.<id>
0x05 SmartLithium -> electrical.batteries.<id>
0x06 Inverter RS -> electrical.inverters.<id>
0x09 Smart Battery Protect -> diagnostic only
0x0B Multi RS -> diagnostic only
0x0C VE.Bus -> diagnostic only
0x0D DC energy meter -> diagnostic onlyThe battery monitor and DC energy meter records carry a 16-bit auxiliary field whose meaning depends on a 2-bit selector stored after it: starter voltage, mid-point voltage, or temperature. Only the selected reading is returned; the others are null, because the same bits mean different things per device configuration. Starter and mid-point voltage have no Signal K leaf, so they appear in the status API only. The DC energy meter has no mid-point reading, so that selector is rejected for it rather than producing a value the record does not carry.
SmartLithium cell voltages are reported as a bound and a voltage, because the specification defines the two end values as thresholds rather than measurements:
{ bound: 'below', voltage_v: 2.61 } cell is under 2.61 V, no lower bound given
{ bound: 'exact', voltage_v: 3.25 } a measurement
{ bound: 'above', voltage_v: 3.85 } cell is over 3.85 V, no upper bound given
null not availableAn unavailable cell keeps its position in the list, so cell numbering stays meaningful when one reading is missing.
Records 0x07 and 0x08 are not implemented. The specification marks both
layouts as still to be determined and subject to change, so decoding them
would be guesswork.
If you have any of these devices, please compare the plugin values with VictronConnect and report the result. Do not post advertisement keys, and mask MAC addresses in any capture you share.