smart-grid-controller
v1.1.2
Published
Intelligent AC grid management for Victron MultiPlus II with load-based switching, battery protection, and scheduled charging
Downloads
16
Maintainers
Readme
Smart Grid Controller for Signal K
Intelligent AC grid management plugin for Victron MultiPlus II systems. Automatically controls when grid power is connected based on battery state, power demand, scheduled charging windows, and comprehensive safety protections.
📦 Install: npm install smart-grid-controller or via Signal K App Store
⚠️ CRITICAL CONFIGURATION WARNING
This plugin MUST be configured for your specific battery type before use!
Default settings are for Li-NCM 15S (55.5V nominal) batteries. Using wrong voltage thresholds for your battery chemistry could result in:
- Battery damage from over/under voltage
- Fire or explosion risk
- System failure during critical moments
Always configure your battery type in the Signal K admin panel before enabling the plugin.
Features
Four Enable Conditions (grid connects if ANY condition is met)
- High Load: AC load >2500W for 3+ seconds (configurable)
- Low Voltage: Battery voltage drops below threshold for 3+ seconds (auto-set by battery type)
- Low Battery: State of charge <10% for 3+ seconds (configurable)
- Scheduled Charging: Configurable time window (default 00:00-06:00 UK time)
Multi-Layer Battery Protection
- Standard Protection: Disconnects at high voltage/SoC (auto-set by battery type, can be overridden by high loads)
- Emergency Protection: Immediately disconnects at critical voltage (auto-set by battery type, cannot be overridden)
Smart Timing
- 3-second delays prevent false triggers from momentary spikes
- 30-second grace period before disconnecting when conditions clear
- Hysteresis thresholds prevent rapid cycling
Installation & Configuration
- Install Plugin:
- Via Signal K App Store: Admin UI → AppStore → Electrical → Smart Grid Controller → Install
- Via npm:
npm install smart-grid-controller - Package Info: View on npm
- BEFORE ENABLING: Configure your battery type in Signal K admin panel
- CRITICAL: Verify all voltage thresholds match your battery specifications
- Test in safe conditions with monitoring
- Wire hardware according to your setup (see Hardware Configuration below)
Supported Battery Types
- Li-NCM 15S (55.5V nominal) - High energy density systems
- LiFePO4 16S (51.2V nominal) - High voltage LiFePO4 systems
Configuration Parameters
Access through Signal K admin panel → Plugin Config → Smart Grid Controller:
- Battery Chemistry: Select your battery type for automatic safe defaults
- Load Thresholds: Customize high-load switching points
- SoC Limits: Adjust state-of-charge behavior
- Schedule Settings: Modify charging window and timezone
Requirements
- Option A: MultiPlus II GX (built-in GX device) - No external hardware needed
- Option B: Cerbo GX with VenusOS "Large" firmware + external contactor
- Signal K server with Victron plugin
- Properly configured battery settings
Hardware Configuration
Option A: MultiPlus II GX (Recommended)
Grid AC ──► MultiPlus II GX ──► AC Loads
│
└─ Built-in GX controls AC input directly- ✅ No external contactor needed
- ✅ Direct AC input enable/disable control
- ✅ Cleaner, more reliable control
- ✅ AC input current limits configured in Victron settings
Option B: External Cerbo GX + Contactor
Grid AC ──► [Contactor] ──► MultiPlus II AC Input
│
└─ Cerbo GX Relay 1 Output- Requires external contactor wired to Cerbo GX Relay 1
- For systems with separate Cerbo GX units
Configuration
Control Method Settings
- Auto-detect (Recommended): Plugin tries both control methods
- MultiPlus II GX: For systems with built-in GX (your setup!)
- Cerbo GX: For external Cerbo GX with relay control
For MultiPlus II GX Users:
- Set Control Method: "MultiPlus II GX (built-in GX)"
- No external wiring needed - plugin controls AC input directly
- AC input current limits: Configure in Victron system settings (not in this plugin)
Safety Notes
- Verify configuration before first use
- Plugin includes emergency protection but proper configuration is essential
- Test thoroughly in safe conditions with monitoring
- Ensure proper contactor ratings for your system
- Monitor system logs during initial operation
- Have qualified electrical support available
Troubleshooting
Plugin Not Working
- Check Signal K logs for error messages from "Smart Grid Controller"
- Verify data paths - ensure Victron plugin is running and data is available:
electrical.chargers.275.voltage(battery voltage)electrical.inverters.275.acout.power(AC load)- MultiPlus II GX:
electrical.inverters.275.acState.ignoreAcIn1.state(AC input control) - Cerbo GX:
electrical.switches.relay1.state(relay control)
- Test control manually in Signal K admin: Server → Data Browser → navigate to control path
Common Issues
- No relay control: Check Cerbo GX relay configuration and wiring
- Invalid data warnings: Verify Victron system is connected and providing data
- Timezone errors: Ensure timezone string is valid (e.g., "Europe/London", "America/New_York")
- Rapid switching: Adjust hysteresis gaps in configuration
Getting Help
- Check Signal K server logs for detailed error messages
- Verify all configuration parameters are within valid ranges
- Test individual components (relay, voltage readings, load measurements)
- Join Signal K community forums for support
Version History
- v1.0.0: Initial release with Li-NCM 15S and LiFePO4 16S support
Contributing
Issues and pull requests welcome at the GitHub repository.