victron-tcp
v1.1.1
Published
MCP server for Victron Energy GX devices via Modbus TCP or MQTT
Downloads
313
Maintainers
Readme
Victron TCP — MCP Server
An MCP (Model Context Protocol) server that connects to Victron Energy GX devices via Modbus TCP or MQTT on your local network. Get direct, low-latency access to real-time solar, battery, grid, and inverter data — no cloud required.
Built from the official CCGX Modbus TCP register list (Rev 50, 900+ registers across 33 device categories). Supports both Modbus TCP (direct register reads) and MQTT (Venus OS built-in broker) transports.
Features
- 28 specialized tools for reading Victron device data
- Dual transport — Modbus TCP (port 502) or MQTT (port 1883), selectable per request or via environment variables
- 900+ registers from the complete Modbus TCP register map
- 33 device categories — system, battery, solar, inverter, grid, genset, alternator, charger, DC-DC, tank, temperature, GPS, meteo, and more
- MQTT auto-discovery — detect portal ID, list all services with device instances, and get ready-to-paste config
- Device discovery — automatically find all connected devices and their unit IDs (Modbus) or service instances (MQTT)
- Generic category reader — read any device category by service name, even those without a dedicated tool
- Raw register access — read any register by address for advanced use
- Environment variable config — set
VICTRON_HOST,VICTRON_TRANSPORT,VICTRON_PORTAL_IDonce, skip repetitive parameters - Stateless connections — connect-per-request, no persistent state to manage
- Read-only — Phase 1 is read-only, all tools annotated with
readOnlyHint: true
Supported Devices
Works with any Victron GX device running Venus OS with Modbus TCP or MQTT enabled:
| Device | Description | |--------|-------------| | Ekrano GX | Touch-screen GX device with 7" display | | Cerbo GX | Most popular GX device, versatile connectivity | | Venus GX | Original GX device | | CCGX | Color Control GX (legacy) | | Octo GX | 8 VE.Direct ports for large systems | | MultiPlus-II GX | Inverter/charger with built-in GX | | EasySolar-II GX | All-in-one solar solution with GX | | GlobalLink 520 | Remote monitoring gateway |
Also works with any device running Venus OS Large, including Raspberry Pi installations.
Supported Accessories
These accessories connect to a GX device via USB or VE.Direct and their data is accessible through the GX device's Modbus TCP interface:
| Accessory | Connection | Data Available Via |
|-----------|------------|-------------------|
| GX IO-Extender 150 | USB | Digital inputs/outputs, relays → digitalinput registers |
| GX Tank 140 | USB | Tank levels → victron_tank_levels |
| GX LTE 4G / GX GSM | USB | Connectivity module (no register data) |
| VE.Direct devices (MPPT, BMV, Phoenix, etc.) | VE.Direct | Solar → victron_solar_status, Battery → victron_battery_status, Inverter → victron_inverter_status |
| VE.Bus devices (Multi, Quattro) | VE.Bus | victron_vebus_status |
| VE.Can devices (Lynx, MPPT RS, etc.) | VE.Can | Various tools depending on device type |
| Energy meters (EM24, EM540, ET series) | Wired/wireless | victron_grid_status |
| Temperature sensors | Connected via GX or IO-Extender | victron_temperature |
All accessory data flows through the GX device — you always connect to the GX device's IP address, never to the accessories directly.
Prerequisites
- A Victron GX device on your local network
- At least one transport enabled on the GX device:
- Modbus TCP: Go to Settings → Services → Modbus TCP → Enable (or Settings → Integrations → Modbus TCP server on Venus OS 3.x)
- MQTT: Enabled by default on Venus OS. The built-in MQTT broker runs on port 1883 with no authentication.
- Node.js 18+ installed
Installation
Option 1: npx (no install needed)
npx victron-tcpOption 2: Clone and build
git clone https://github.com/lubosstrejcek/victron-tcp.git
cd victron-tcp
npm install
npm run buildQuick Start
Claude Code (recommended)
The fastest way — one command:
claude mcp add --transport stdio victron-tcp -- npx victron-tcpOr if you built from source:
claude mcp add --transport stdio victron-tcp -- node /absolute/path/to/victron-tcp/dist/index.jsClaude Code — with environment variables
Pre-configure the host and transport so you don't have to pass them on every tool call:
claude mcp add --transport stdio \
-e VICTRON_HOST=192.168.1.50 \
-e VICTRON_TRANSPORT=mqtt \
-e VICTRON_PORTAL_ID=ca0f0e2e2261 \
victron-tcp -- npx victron-tcpClaude Code — Project scope (share with your team)
Add a .mcp.json file to your project root and commit it:
{
"mcpServers": {
"victron-tcp": {
"command": "npx",
"args": ["victron-tcp"],
"env": {
"VICTRON_HOST": "192.168.1.50",
"VICTRON_TRANSPORT": "mqtt",
"VICTRON_PORTAL_ID": "your-portal-id"
}
}
}
}Omit the env block to pass parameters per tool call instead.
Claude Code — User scope (all your projects)
claude mcp add --transport stdio --scope user victron-tcp -- npx victron-tcpClaude Desktop
Add to your Claude Desktop config (~/Library/Application Support/Claude/claude_desktop_config.json on macOS):
{
"mcpServers": {
"victron-tcp": {
"command": "npx",
"args": ["-y", "victron-tcp"],
"env": {
"VICTRON_HOST": "192.168.1.50",
"VICTRON_TRANSPORT": "mqtt",
"VICTRON_PORTAL_ID": "your-portal-id"
}
}
}
}Cursor
Add to .cursor/mcp.json in your project root (or ~/.cursor/mcp.json for all projects):
{
"mcpServers": {
"victron-tcp": {
"command": "npx",
"args": ["-y", "victron-tcp"],
"env": {
"VICTRON_HOST": "192.168.1.50",
"VICTRON_TRANSPORT": "mqtt",
"VICTRON_PORTAL_ID": "your-portal-id"
}
}
}
}Windsurf
Add to ~/.codeium/windsurf/mcp_config.json:
{
"mcpServers": {
"victron-tcp": {
"command": "npx",
"args": ["-y", "victron-tcp"],
"env": {
"VICTRON_HOST": "192.168.1.50",
"VICTRON_TRANSPORT": "mqtt",
"VICTRON_PORTAL_ID": "your-portal-id"
}
}
}
}Other MCP Clients
The server uses stdio transport. The JSON format is the same — mcpServers → command + args + env. Add it to your client's MCP configuration file.
Available Tools
Core Monitoring Tools
| Tool | Description | Default Unit ID |
|------|-------------|-----------------|
| victron_system_overview | Battery SOC, voltage, current, PV power, grid power, AC consumption, Dynamic ESS status | 100 |
| victron_battery_status | Detailed battery: SOC, voltage, current, power, temperature, cell data, time-to-go, history | per device |
| victron_solar_status | PV voltage, current, power, yield today/yesterday/total, charger state, tracker data | per device |
| victron_grid_status | Grid power per phase (L1/L2/L3), voltage, current, frequency, energy counters | per device |
| victron_vebus_status | Multi/Quattro: AC in/out power, input current limit, mode, state, alarms, ESS settings | per device |
| victron_tank_levels | Tank level, capacity, remaining, fluid type (fuel, fresh water, waste, etc.) | per device |
| victron_temperature | Temperature readings with sensor type (battery, fridge, generic), humidity, pressure | per device |
| victron_inverter_status | Standalone inverter: AC output, state, alarms (Phoenix, Inverter RS) | per device |
| victron_evcs_status | EV Charging Station (direct connection): power, status, session energy, temperatures | 1 |
Extended Device Tools
| Tool | Description | Default Unit ID |
|------|-------------|-----------------|
| victron_multi_status | Multi RS inverter/charger: AC in/out per phase, battery data, charge/inverter state, alarms | 100 |
| victron_pvinverter_status | AC-coupled PV inverters (Fronius, SolarEdge, ABB): power per phase, energy totals, power limit | 31 |
| victron_genset_status | AC genset controllers (Fischer Panda, ComAp, DSE, CRE, DEIF): 3-phase AC, engine data, oil/coolant/exhaust temps | 23 |
| victron_dcgenset_status | DC generators (Fischer Panda, Hatz fiPMG): DC voltage/current, engine data, temperatures, error codes | 100 |
| victron_alternator_status | NMEA 2000 alternators (Wakespeed WS500, Arco Zeus, Revatek Altion): voltage/current, RPM, field drive % | 100 |
| victron_charger_status | AC chargers (Skylla-i, Skylla-IP44, Smart IP43, Blue Smart IP22): up to 3 outputs, charge state, alarms | 100 |
| victron_dcdc_status | Orion XS DC-DC converter: battery voltage/current/temperature, input power, charge state | 100 |
| victron_acload_status | AC load / current sensors: per-phase power, voltage, current, energy totals, frequency | 100 |
| victron_dcenergy_status | DC energy meters (SmartShunts in DC meter mode): voltage, current, energy. Types: source, load, system | 100 |
| victron_gx_info | GX device identity: serial number, relay states, system time | 100 |
| victron_digital_inputs | Digital input state (open/closed), input type (door, bilge, alarm, generator), pulse count | 100 |
| victron_gps_status | GPS position: latitude, longitude, altitude, course, speed, fix status, satellite count | 100 |
| victron_meteo_status | IMT Solar irradiance sensors: irradiance (W/m²), wind speed, cell/external temperatures | 100 |
| victron_generator_status | GX generator auto start/stop: runtime, start condition, quiet hours, service countdown, alarms | 100 |
Discovery & Utility Tools
| Tool | Description |
|------|-------------|
| victron_mqtt_discover | Auto-discover portal ID, list all MQTT services and device instances, output ready-to-paste config |
| victron_discover | Scan Modbus unit IDs to find all connected devices and their types |
| victron_read_category | Read all registers for any device category by service name (partial match supported) |
| victron_read_register | Read raw register(s) by address — advanced/debugging (Modbus only) |
| victron_list_registers | List all available registers for a device category |
Tool Annotations
All tools include MCP tool annotations for better client integration:
| Annotation | Value | Meaning |
|------------|-------|---------|
| readOnlyHint | true | Tools only read data, never modify device state |
| destructiveHint | false | No risk of data loss or system changes |
| idempotentHint | true | Safe to call repeatedly with same parameters |
| openWorldHint | false | Operates on local network only (except victron_discover which scans the LAN and victron_evcs_status which connects to EVCS devices) |
Common Parameters
All monitoring tools accept:
| Parameter | Type | Default | Description |
|-----------|------|---------|-------------|
| host | string | required* | GX device IP address or hostname |
| port | number | 502 | Modbus TCP port |
| unitId | number | varies | Modbus unit ID (use victron_discover to find) |
| transport | string | "modbus" | Transport protocol: "modbus" or "mqtt" |
| mqttHost | string | same as host | MQTT broker hostname (if different from Modbus host) |
| mqttPort | number | 1883 | MQTT broker port |
| portalId | string | — | Venus OS portal ID for MQTT (use victron_mqtt_discover to find) |
| deviceInstance | string/number | — | MQTT device instance (omit to auto-detect via wildcard) |
*Can be set via VICTRON_HOST environment variable.
Environment Variables
Set these to avoid repeating parameters on every tool call:
| Variable | Description | Example |
|----------|-------------|---------|
| VICTRON_HOST | Default host for all connections | 192.168.1.50 |
| VICTRON_TRANSPORT | Default transport (modbus or mqtt) | mqtt |
| VICTRON_MODBUS_PORT | Default Modbus TCP port | 502 |
| VICTRON_MQTT_PORT | Default MQTT broker port | 1883 |
| VICTRON_PORTAL_ID | Default portal ID for MQTT | ca0f0e2e2261 |
| VICTRON_UNIT_ID | Default Modbus unit ID | 100 |
Tool arguments always override environment variables.
Usage Examples
Example 1: Discover your system
Prompt:
What Victron devices are connected to my GX at 192.168.1.50?What the AI will do:
- Call
victron_discoverwith host192.168.1.50 - Scan unit IDs 0–247, probing each for known device types
- Return a table of all connected devices with their unit IDs, service types, and names
Example 2: Full system overview
Prompt:
Show me the current state of my solar system at 192.168.1.50 — battery, solar, grid, everything.What the AI will do:
- Call
victron_system_overviewto get battery SOC, voltage, current, PV power, grid import/export, AC consumption, and ESS status - Present the data in a readable summary with all key metrics
Example 3: Monitor battery health
Prompt:
How is my battery doing? GX is at 192.168.1.50, battery monitor is unit 225.
I want SOC, voltage, temperature, and time-to-go.What the AI will do:
- Call
victron_battery_statuswith host and unitId 225 - Read all 108 battery registers: SOC, voltage, current, power, temperature, cell min/max, consumed Ah, time-to-go, cycle history
- Highlight any concerning values (low SOC, high temperature, cell imbalance)
Example 4: Check solar production
Prompt:
What's my solar production right now and how much energy did I generate today?
GX at 192.168.1.50, solar charger unit 226.What the AI will do:
- Call
victron_solar_statuswith unitId 226 - Read PV voltage, current, power, charger state, yield today/yesterday/total, and tracker data
- Show current production and daily energy yield
Example 5: Multi-phase grid analysis
Prompt:
Show me the grid power on all three phases. Are we importing or exporting?
GX at 192.168.1.50, grid meter unit 30.What the AI will do:
- Call
victron_grid_statuswith unitId 30 - Read per-phase power (L1/L2/L3), voltage, current, frequency, and energy counters
- Calculate total grid power and indicate import (positive) vs export (negative)
Example 6: Monitor all tanks
Prompt:
What are my tank levels? I have a fresh water tank on unit 20
and a fuel tank on unit 21. GX at 192.168.1.50.What the AI will do:
- Call
victron_tank_levelsfor each unit ID (20 and 21) - Read tank level percentage, capacity, remaining volume, fluid type, and status
- Present a clear summary of each tank
Example 7: Inverter/charger status (Multi or Quattro)
Prompt:
What's the status of my MultiPlus-II? Check AC input, AC output, current limits,
and any active alarms. GX at 192.168.1.50, VE.Bus unit 227.What the AI will do:
- Call
victron_vebus_statuswith unitId 227 - Read AC input/output voltage, current, power per phase, input current limit, mode, state, alarms, and ESS settings
- Flag any active alarms or warnings
Example 8: Read a specific register by address
Prompt:
Read register 840 (battery voltage) at unit 100 from my GX at 192.168.1.50.
It's a uint16 with scale factor 10.What the AI will do:
- Call
victron_read_registerwith address 840, dataType "uint16", scaleFactor 10 - Return the raw and decoded value (e.g., raw 488 → 48.8V)
Example 9: Explore available registers
Prompt:
What registers are available for the solar charger? I want to know what data I can read.What the AI will do:
- Call
victron_list_registerswith category "solarcharger" - Return all 55 registers with their address, name, data type, unit, and dbus path
Example 10: Daily energy report
Prompt:
Give me a daily energy report for my system at 192.168.1.50.
I want solar yield, grid import/export, battery cycles, and total consumption.
Solar charger is unit 226, grid meter is unit 30, VE.Bus is unit 227.What the AI will do:
- Call
victron_system_overviewfor overall consumption and battery data - Call
victron_solar_status(unit 226) for today's solar yield - Call
victron_grid_status(unit 30) for grid energy counters - Call
victron_vebus_status(unit 227) for inverter/charger energy data - Compile all data into a comprehensive daily energy report
Example 11: EV Charging Station status
Prompt:
What's the status of my Victron EV Charging Station? It's at 192.168.1.60.
Is it charging? How much power is it using? What's the session energy so far?What the AI will do:
- Call
victron_evcs_statuswith host192.168.1.60(connecting directly to the EVCS, not the GX) - Read charger status, L1/L2/L3 power, charging current, mode, session energy, temperatures
- Show charging status with human-readable labels (Disconnected, Charging, Charged, etc.)
Example 12: Discover MQTT services
Prompt:
Discover what services are available via MQTT on my GX at 192.168.1.50.What the AI will do:
- Call
victron_mqtt_discoverwith mqttHost192.168.1.50 - Auto-detect the portal ID from the MQTT broker
- List all available services (battery, solarcharger, vebus, grid, etc.) with their device instances
- Output a ready-to-paste MCP server config with the discovered portal ID and environment variables
Example 13: Read data via MQTT
Prompt:
Show me battery status via MQTT. GX at 192.168.1.50, portal ID ca0f0e2e2261.What the AI will do:
- Call
victron_battery_statuswithtransport: "mqtt", host192.168.1.50, portalIdca0f0e2e2261 - Subscribe to MQTT topics for battery data, collect pre-scaled values
- Return the same formatted output as the Modbus path — SOC, voltage, current, temperature, etc.
Modbus TCP vs MQTT
| | Modbus TCP | MQTT |
|---|-----------|------|
| Port | 502 | 1883 |
| Setup | Must enable on GX | Enabled by default |
| Device addressing | Unit ID (0–247) | Service type + device instance |
| Discovery | victron_discover (scans unit IDs) | victron_mqtt_discover (instant) |
| Data format | Raw registers with scale factors | Pre-scaled JSON values |
| Best for | Direct register access, raw reads | Easy setup, no unit ID hunting |
| Limitations | Must enable Modbus TCP on GX, unit IDs are dynamic | Requires portal ID (auto-discovered) |
Both transports return identical output. You can switch between them by changing the transport parameter or the VICTRON_TRANSPORT environment variable.
Finding Unit IDs
Unit IDs identify specific devices on the Modbus bus. There are two ways to find them:
1. Use the discover tool
The victron_discover tool scans unit IDs 0-247 and reports what it finds. This is the easiest method.
2. Check the GX device
On the GX device, go to:
- Settings → Integrations → Modbus TCP server → Available services
- This shows each service with its assigned unit ID
Common Unit ID Defaults
| Unit ID | Service | |---------|---------| | 100 | System overview (com.victronenergy.system) | | 227 | VE.Bus (first Multi/Quattro on Cerbo GX) | | 247 | First VE.Direct device (CCGX) | | 226 | VE.Direct port 1 (Cerbo GX) |
Note: Since Venus OS 2.60, unit IDs are assigned dynamically. Always verify with victron_discover or the GX device settings.
Register Map
The complete register map is derived from Victron's official CCGX Modbus TCP register list v3.60 (Rev 50). It covers 33 device categories:
| Category | Service | Registers | |----------|---------|-----------| | System | com.victronenergy.system | 53 | | Battery | com.victronenergy.battery | 108 | | VE.Bus | com.victronenergy.vebus | 94 | | Solar Charger | com.victronenergy.solarcharger | 55 | | Inverter | com.victronenergy.inverter | 51 | | Genset | com.victronenergy.genset | 45 | | Multi RS | com.victronenergy.multi | 105 | | AC System | com.victronenergy.acsystem | 42 | | EVCS (direct) | victron.evcs | 42 | | Settings | com.victronenergy.settings | 34 | | Grid Meter | com.victronenergy.grid | 32 | | DC Genset | com.victronenergy.dcgenset | 26 | | PV Inverter | com.victronenergy.pvinverter | 24 | | AC Load | com.victronenergy.acload | 22 | | Alternator | com.victronenergy.alternator | 20 | | EV Charger (via GX) | com.victronenergy.evcharger | 17 | | Charger | com.victronenergy.charger | 16 | | DC System | com.victronenergy.dcsystem | 12 | | Fuel Cell | com.victronenergy.fuelcell | 11 | | DC Source | com.victronenergy.dcsource | 11 | | DC Load | com.victronenergy.dcload | 11 | | DC-DC | com.victronenergy.dcdc | 11 | | Generator | com.victronenergy.generator | 11 | | Temperature | com.victronenergy.temperature | 9 | | GPS | com.victronenergy.gps | 7 | | Tank | com.victronenergy.tank | 6 | | Motor Drive | com.victronenergy.motordrive | 6 | | Heat Pump | com.victronenergy.heatpump | 6 | | Meteo | com.victronenergy.meteo | 5 | | Digital Input | com.victronenergy.digitalinput | 4 | | Pulse Meter | com.victronenergy.pulsemeter | 2 | | Hub-4 | com.victronenergy.hub4 | 2 | | Pump | com.victronenergy.pump | 1 |
Architecture
victron-tcp/
├── src/
│ ├── index.ts # Entry point (stdio transport)
│ ├── server.ts # MCP server setup
│ ├── config.ts # Environment variable config (VICTRON_HOST, VICTRON_TRANSPORT, etc.)
│ ├── transport.ts # Unified transport abstraction (Modbus or MQTT → same result)
│ ├── modbus/
│ │ ├── client.ts # Modbus TCP client + withModbusClient() wrapper
│ │ ├── decoders.ts # Data decoding, batch grouping, error wrapping
│ │ └── types.ts # RegisterDefinition, RegisterCategory interfaces
│ ├── mqtt/
│ │ ├── client.ts # VictronMqttClient + withMqttClient() wrapper
│ │ └── decoders.ts # MQTT topic building, payload parsing, value conversion
│ ├── registers/
│ │ ├── index.ts # Named exports for all 33 categories
│ │ └── loader.ts # Loads JSON register databases at import time
│ └── tools/ # MCP tool implementations (one file per device type)
│ ├── index.ts # registerAllTools() — wires all 28 tools
│ ├── helpers.ts # Shared schemas, transport params, formatResults(), errorResult()
│ ├── mqtt-discover.ts # victron_mqtt_discover
│ ├── system.ts # victron_system_overview
│ ├── battery.ts # victron_battery_status
│ ├── solar.ts # victron_solar_status
│ ├── grid.ts # victron_grid_status
│ ├── vebus.ts # victron_vebus_status
│ ├── tanks.ts # victron_tank_levels
│ ├── temperature.ts # victron_temperature
│ ├── inverter.ts # victron_inverter_status
│ ├── evcs.ts # victron_evcs_status (Modbus only — direct EVCS connection)
│ ├── multi.ts # victron_multi_status
│ ├── pvinverter.ts # victron_pvinverter_status
│ ├── genset.ts # victron_genset_status
│ ├── dcgenset.ts # victron_dcgenset_status
│ ├── alternator.ts # victron_alternator_status
│ ├── charger.ts # victron_charger_status
│ ├── dcdc.ts # victron_dcdc_status
│ ├── acload.ts # victron_acload_status
│ ├── dcenergy.ts # victron_dcenergy_status
│ ├── gx-info.ts # victron_gx_info
│ ├── digital-inputs.ts # victron_digital_inputs
│ ├── gps.ts # victron_gps_status
│ ├── meteo.ts # victron_meteo_status
│ ├── generator.ts # victron_generator_status
│ ├── discover.ts # victron_discover (Modbus only — scans unit IDs)
│ ├── category.ts # victron_read_category
│ └── raw.ts # victron_read_register + victron_list_registers (Modbus only)
├── data/
│ ├── ccgx-registers.json # 859 registers across 32 CCGX categories
│ ├── evcs-registers.json # 42 EVCS direct connection registers
│ ├── enum-overrides.json # Human-readable labels for enum values
│ └── ess-control-registers.json # Reserved for Phase 2 write support
├── tests/ # Vitest test suite
├── scripts/
│ ├── convert-excel.ts # Convert Victron Excel spreadsheet → JSON
│ └── modbus-simulator.ts # Local Modbus TCP simulator for testing
├── server.json # MCP Registry metadata
└── dist/ # Compiled outputHow It Works
Modbus TCP transport (default)
- Connection per request — Each tool call opens a Modbus TCP connection, reads the requested registers, and closes the connection. Simple and stateless.
- Batch reads — Consecutive registers are read in a single Modbus request for efficiency.
- Data decoding — Raw register values are decoded according to their data type (uint16, int16, uint32, int32, uint64, string) and scale factor.
- Enum mapping — Numeric values are mapped to human-readable labels where applicable (e.g., battery state: 0 → "Idle", 1 → "Charging", 2 → "Discharging").
- Disconnected detection — Values like 0xFFFF (uint16) or 0x7FFF (int16) indicate a disconnected sensor and are shown as "Not available".
- Error handling — Modbus errors return
isError: truewith actionable messages, allowing the LLM to self-correct (e.g., suggest checking the unit ID).
MQTT transport
- Connection per request — Each tool call connects to the Venus OS MQTT broker, subscribes to topics, collects data, and disconnects.
- Topic structure — Data lives at
N/{portalId}/{serviceType}/{deviceInstance}/{dbusPath}. The server subscribes to the relevant topics for each register. - Pre-scaled values — Venus OS publishes already-scaled values via MQTT (JSON
{"value": ...}), so no scale factor math is needed. - Keepalive — The server publishes to
R/{portalId}/keepaliveto trigger data publication from the GX device. - Wildcard discovery — When
deviceInstanceis omitted, the server uses MQTT wildcards (+) to find the first matching device automatically. - Same output — Both transports produce identical
RegisterReadResultarrays, so tools and formatting work unchanged.
Troubleshooting
"Connection timeout" or "ECONNREFUSED"
- Verify the GX device IP address is correct
- Check that Modbus TCP is enabled: Settings → Services → Modbus TCP
- Ensure no firewall is blocking port 502
- Try pinging the GX device:
ping 192.168.1.50
"Illegal Data Address" errors
- The register might not be supported by your device/firmware version
- Use
victron_list_registersto see available registers - Check that you're using the correct unit ID for the device
"Gateway Target Device Failed to Respond"
- The unit ID doesn't correspond to any connected device
- Run
victron_discoverto find valid unit IDs - The device might be temporarily offline or disconnected
No devices found during discovery
- Modbus TCP must be enabled on the GX device
- The scan range might not include your device's unit ID
- Try specifying a narrower range if the scan is timing out
MQTT "Connection timeout"
- Verify the GX device IP address is correct
- Check that the MQTT broker is running:
mosquitto_sub -h 192.168.1.50 -t '#' -C 1 - The default MQTT port is 1883 (no authentication required)
- Venus OS enables MQTT by default — if it's not working, the device may not be reachable
MQTT "Portal ID discovery timeout"
- The GX device may need a moment to start publishing after boot
- Try running
victron_mqtt_discoveragain after a few seconds - Verify the MQTT broker has data:
mosquitto_sub -h 192.168.1.50 -t 'N/+/system/+/Serial' -C 1
MQTT returns "Not available" for all registers
- The portal ID may be incorrect — run
victron_mqtt_discoverto auto-detect it - The device instance may not match — omit
deviceInstanceto use wildcard auto-detection - Publish a keepalive to trigger data: the server does this automatically, but stale brokers may need a moment
Debugging on the GX device
- Error log on the GX: Go to Settings → Services → Modbus TCP — the last error is shown on this page
- SSH debug log: Connect via SSH and check
/var/log/dbus-modbustcp/currentfor detailed request/error logs - Unit ID mapping: The GX assigns unit IDs dynamically. Check Settings → Services → Modbus TCP → Available services to see the current mapping
FAQ
Any Victron GX device (Ekrano, Cerbo, Venus GX, CCGX, etc.) on the same local network. MQTT is enabled by default — no configuration needed. For Modbus TCP, enable it in the GX device settings. No cloud account or VRM portal access is required.
On the GX device, go to Settings → Services → Modbus TCP and enable it. On Venus OS 3.x, the path may be Settings → Integrations → Modbus TCP server. The default port is 502.
Check your router's DHCP client list, or look on the GX device itself under Settings → Ethernet or Settings → WiFi. You can also try ping cerbo.local or ping venus.local if mDNS is supported on your network.
Unit IDs are Modbus addresses that identify specific devices on the GX bus. Unit ID 100 is always the system overview. Other devices get dynamically assigned IDs. Use the victron_discover tool to scan all unit IDs, or check the GX device at Settings → Services → Modbus TCP → Available services.
Both transports return identical data. MQTT is easier to set up — it's enabled by default, doesn't require unit IDs, and auto-discovers devices. Modbus TCP gives you raw register access and works with the victron_read_register tool for advanced debugging. If you're unsure, start with MQTT and victron_mqtt_discover.
The portal ID is a unique identifier for your Venus OS installation (e.g., ca0f0e2e2261). It's used as the root of all MQTT topics. Run victron_mqtt_discover to auto-detect it, or find it on the GX device under Settings → VRM online portal → VRM Portal ID.
Yes. When you omit the deviceInstance parameter, the server uses MQTT wildcard subscriptions (+) to automatically find the first matching device for each service type. This works for most setups. If you have multiple devices of the same type, specify the instance to target a specific one.
Not yet. Phase 1 is read-only — all tools are annotated with readOnlyHint: true. Phase 2 will add write support for ESS mode control, grid setpoints, charge current limits, and relay control.
Yes, fully. Two options: (1) Use victron_evcs_status to connect directly to the EVCS device's own Modbus TCP server (42 registers — power per phase, status, session energy, mode, temperatures, error codes). (2) Read the 17 GX-proxied registers via victron_read_category with category "evcharger" if the EVCS is connected through a GX device.
901 registers across 33 device categories — the complete official CCGX Modbus TCP register list v3.60 (Rev 50) with 859 registers, plus 42 registers for direct EV Charging Station connections. Every service from com.victronenergy.system to com.victronenergy.pump is included.
Yes, it's safe. Phase 1 is completely read-only. The server never writes to any registers. All tools are annotated with readOnlyHint: true and destructiveHint: false. Each connection is opened, registers are read, and the connection is closed — no persistent state.
Yes. Any device running Venus OS works — including Raspberry Pi installations running Venus OS Large. Both Modbus TCP and MQTT transports are supported.
Any MCP client that supports stdio transport: Claude Code, Claude Desktop, Cursor, Windsurf, Cline, and others. See the Quick Start section for setup instructions for each client.
No. Set environment variables (VICTRON_HOST, VICTRON_TRANSPORT, VICTRON_PORTAL_ID) in your MCP client config and they'll be used as defaults. Tool arguments override env vars when provided. See the Environment Variables section for the full list.
MCP is an open standard that lets AI assistants call external tools. This server exposes Victron device data as MCP tools — the AI decides which tool to call based on your question, reads the data, and presents it in a readable format. You don't need to know register addresses or device protocols.
This server is designed for AI assistants via MCP, not for general-purpose automation. For Home Assistant, use the Victron integration or direct Modbus TCP. For Node-RED, use the modbus or MQTT nodes directly. This server adds value when you want an AI to interpret and reason about the data.
Claude Desktop Extension
This server is also available as a Claude Desktop Extension (.mcpb) for one-click installation:
- Download the
.mcpbfile from the Releases page - Double-click to open with Claude Desktop
- Click Install
To build the extension from source:
npm run build
npx @anthropic-ai/mcpb packRoadmap
- [ ] Phase 2: Write support — ESS mode control, grid setpoint, charge current limits, relay control (registers 2700–2709, Mode 2/3 setpoints)
- [ ] Phase 3: Resources — real-time monitoring via MCP resources with SSE subscriptions
- [x] Claude Desktop Extension packaging (
.mcpb) - [x] NPM package publishing (
npx victron-tcp)
References
- Victron Modbus TCP FAQ
- CCGX Modbus TCP Register List (Excel)
- ESS Design & Installation Manual
- Venus OS on GitHub
- MCP Protocol Specification
- MCP Tools Specification
- Venus OS MQTT documentation
- venus-docker — Venus OS simulator
- modbus-serial npm package
- mqtt.js npm package
License
MIT